Catalog item

TERMINAL BOARD

5940FSC
00NCB code
949-3125Item number
NIIN 00-949-3125
Request a quote
Unit price
$572.00
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00404
PINC
0000404
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
20-APR-66
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8536908085

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$572.001U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$572.001U0NSF9EH-N$0.00F
01-OCT-2026DMJSMSEA0.0000$572.001U0Z15B2---$0.00M
01-OCT-2026DNJSMSEA0.0000$572.001U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$572.001U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
605-JJ-0426405
REGAL BELOIT AMERICA, INC
A324CX
4-152B271785
CINCH CONNECTIVITY SOLUTIONS INC.
AC13TU4B
356-31-04-07171785
CINCH CONNECTIVITY SOLUTIONS INC.
A324CX3D
605JJ483330
DIALIGHT CORPORATION
A594CXB

Characteristics

SURFACE TREATMENTTERMINALS NICKEL
MATERIALTERMINALS COPPER ALLOY
MATERIALBOARD PLASTIC DIALLYL PHTHALATE AND GLASS FIBER
MOUNTING HOLE DIAMETERINCHES 0.265
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS2100.0
BODY STYLE
TERMINAL ROW QUANTITY2
CENTER TO CENTER DISTANCE BETWEEN TERMINALSINCHES 1.125
DISTANCE BETWEEN TERMINAL ROW CENTERSINCHES 0.875
BOARD CONSTRUCTIONHOLLOW CONSTRUCTION WITHOUT INSULATED STRIP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHINCHES 5.625
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHINCHES 0.875
BOARD OVERALL HEIGHTINCHES 1.125
TERMINAL PATTERN ARRANGEMENTMULTI-ROW
BOARD HEIGHT EXCLUDING TERMINALSINCHES 1.125
BASE THICKNESSINCHES 0.625
CURRENT RATING IN AMPS90.0
MOUNTING FACILITY TYPE AND QUANTITYUNTHREADED HOLE(S) 4
TERMINAL DESIGNLINKED NONFEEDTHRU
NONFEEDTHRU TERMINAL TYPESINGLE 857
DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITYINCHES 0.312
MATERIAL DOCUMENT AND CLASSIFICATIONBOARD MIL SPEC SINGLE MATERIAL RESPONSE -IL--19833,TYE GDI-30F
TERMINAL CONNECTING LINK TYPESINGLE 1
NONFEEDTHRU TERMINAL QUANTITYSINGLE 4
BOARD OVERALL WIDTHINCHES 2.500
BOARD OVERALL LENGTHINCHES 6.250
TERMINAL CONNECTING LINK QUANTITYSINGLE 4
DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLEINCHES 0.468

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YD01YD01-SEP-16YD81YD
ZC01ZC01-APR-91ZC81ZC
ZJ01ZJ01-APR-25ZJ81ZJ
A918DA1Q01-DEC-04ZCDGX01CD5DCD GXCLA917
FXGGDF1Q01-AUG-04ZSXGX01SX5DGX TUFXCX
MC41DM1Q01-AUG-04ZPAGX01PA5DPA GXMC04
N9BGDN1Q01-AUG-04ZGHGX01GH5DGXHD KEN9GD

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2

Freight

ACTY CD
CX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
738
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.9000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0600
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
96
Dt stdzn dec
05-JUN-1997
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59405940-00-253-8826502-JUL-2026A
59405940-00-643-6226502-JUL-2026A
59405940-00-951-6252502-JUL-2026A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.