Catalog item

TERMINAL BOARD

5940FSC
00NCB code
983-6062Item number
NIIN 00-983-6062
Request a quote
Unit price
$24.32
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00404
PINC
0000404
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-62
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8536908085

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$24.321U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$24.321U0NSF9EH-V$0.00F
01-OCT-2026DMJSMSEA0.0000$24.321U0Z15B2---$0.00M
01-OCT-2026DNJSMSEA0.0000$24.321U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$24.321U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
600D3-4ST2126405
REGAL BELOIT AMERICA, INC
AE85CX4B
440-3/4W-2132241
JAYMAR TERMINAL BOARDS INC
HE83CX4D
353-11-21-00171785
CINCH CONNECTIVITY SOLUTIONS INC.
AC14TUAB
21-24071785
CINCH CONNECTIVITY SOLUTIONS INC.
A51XXX3D
37TB2181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22EXX3D
MIL-T-55164/181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A414CX
600D3-4ST2183330
DIALIGHT CORPORATION
AE85CX4B
5940PL08125709009H
JEDNOLITY INDEKS MATERIALOWY - UNIFORM MATERIAL INDEX
A699WP4B
880MO0006A0199
LEONARDO S.P.A. - ELECTRONICS DIVISION - DEFENCE BUSINESS AREA
A826ZR4A
1276-19-295A0199
LEONARDO S.P.A. - ELECTRONICS DIVISION - DEFENCE BUSINESS AREA
A526ZG4D
1412113150
AXSYS TECHNOLOGIES INC
HE83CX4D
10044135-2118876
US ARMY AVIATION AND MISSILE COMMAND
AC14BDAA

Characteristics

MOUNTING FACILITY TYPE AND QUANTITYUNTHREADED HOLE(S) 4
BOARD OVERALL HEIGHTINCHES 0.484
DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLEINCHES 0.282
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHINCHES 8.281
TERMINAL ROW QUANTITY2
BOARD HEIGHT EXCLUDING TERMINALSINCHES 0.484
BASE THICKNESSINCHES 0.328
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHINCHES 0.312
MATERIAL DOCUMENT AND CLASSIFICATIONBOARD MIL SPEC SINGLE MATERIAL RESPONSE -IL--19833,TYE GDI-30F
DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITYINCHES 0.141
TERMINAL CONNECTING LINK QUANTITYSINGLE 21
NONFEEDTHRU TERMINAL TYPESINGLE 857
TERMINAL CONNECTING LINK TYPESINGLE 1
CURRENT RATING IN AMPS15.0
DISTANCE BETWEEN TERMINAL ROW CENTERSINCHES 0.312
BOARD CONSTRUCTIONHOLLOW CONSTRUCTION WITHOUT INSULATED STRIP
BOARD OVERALL LENGTHINCHES 8.578
BOARD OVERALL WIDTHINCHES 0.875
NONFEEDTHRU TERMINAL QUANTITYSINGLE 21
MATERIALBOARD PLASTIC DIALLYL PHTHALATE AND GLASS FIBER
SURFACE TREATMENTTERMINALS NICKEL
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONTERMINALS FED SPEC SINGLE TREATMENT RESPONSE QQ-N-290,CLASS 1,TYE 8
TERMINAL PATTERN ARRANGEMENTMULTI-ROW
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS3000.0
CENTER TO CENTER DISTANCE BETWEEN TERMINALSINCHES 0.375
TERMINAL DESIGNLINKED NONFEEDTHRU
MOUNTING HOLE DIAMETERINCHES 0.171
BODY STYLE

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
VM01VM01-MAY-25VM81VM
WG01WG01-OCT-17WG81WG
WP01WP01-NOV-06WP81WP
YA01YA01-JAN-02YA81YA
YB01YB01-APR-91YB81YB
YD01YD01-SEP-16YD81YD
YJ01YJ01-APR-91YJ81YJ
ZC01ZC01-APR-91ZC81ZC
ZF01ZF01-APR-91ZF81ZF
ZG01ZG01-APR-91ZG81ZG
ZH01ZH01-APR-91ZH81ZH
ZJ01ZJ01-APR-25ZJ81ZJ
ZN01ZN01-JUL-18ZN81ZN
ZK01ZK01-APR-91ZK81ZK
ZS01ZS01-APR-91ZS81ZS
ZR01ZR01-APR-91ZR81ZR
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-FEB-94ZW81ZW
A918DA1G01-DEC-04ZCDGX01CD5DCD GXBDA917
BGX1GE1G01-AUG-04GX01485DGX 48BCX1
FXGGDF1G01-AUG-04ZSXGX01SX5DGX TUFXCX
G860T10001-APR-91C864875 86
MC41DM1G01-AUG-04ZPAGX01PA5DPA GXMC04
N9BGDN1G01-AUG-04ZGHGX01GH5DGXHD KENIGD
VJ01VJ01-DEC-18VJ81VJ
S911DG1G01-AUG-04ZXNGX01XN5DXN GXS003

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
738
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
A1
Bags made of material conforming to MIL-P-130, or any bag authorized by MIL-DTL-117.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
E5
ASTM D5118/D5118M, fiberboard box.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.2000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0160
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
5940-00-849-09543CX10-JUL-19630
5940-00-794-44503CX28-DEC-19750
5940-00-836-85573CX10-JUL-19630
5940-00-164-42503CX10-JUL-19630
3CX10-JUL-19630
1CX28-DEC-19750
3CX28-DEC-19750

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59405940-00-258-7873501-JUL-2026A
59405940-00-269-6329702-JUL-2026A
59405940-00-606-8229502-JUL-2026A
59405940-00-789-0784502-JUL-2026A
59405940-00-828-6512502-JUL-2026A
59405940-00-957-3778501-JUL-2026A
59405940-00-710-1568502-JUL-2026A
59405940-00-784-1016502-JUL-2026A
59405940-00-754-8551501-JUL-2026A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.