Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
00NCB code
089-8065Item number
NIIN 00-089-8065
Request a quote
Unit price
$249.97
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
22-JUL-67
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8536410050

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$249.971U0ZQ22QAX-$0.00A
01-OCT-2026DFJSMSEA0.0000$249.971U0NSF9EH-V$0.00F
01-OCT-2026DNJSMSEA0.0000$249.971U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$249.971U0N-------$0.00I
01-OCT-2026GPJSMSEA0.0000$249.971U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
BR7-S45756623
MICROSEMI CORP.-POWER MANAGEMENT GROUP
A325TX4D
B07Z992BZ1-004458614
TE CONNECTIVITY CORPORATION
A595TX
07Z992BZ1-004458614
TE CONNECTIVITY CORPORATION
A525ZZ
2073532-070159475
REX SYSTEMS INCORPORATED DBA REX SYSTEMS INC
AC15ZZAC
FC-210-2678290
STRUTHERS-DUNN INC
H595TX4B
07Z992BZ1-004482415
AIRPAX CORPORATION LLC DBA AIRPAX CORPORATION LLC
A595TX4B
B07Z992BZ1-004400779
TE CONNECTIVITY CORPORATION
A525TX
2073532-070106845
RAYTHEON COMPANY DBA RAYTHEON CO
A721KE3D

Characteristics

OVERALL WIDTHINCHES MAXIMUM 0.625
OVERALL LENGTHINCHES NOMINAL 1.750
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSDC 26.5
TERMINAL TYPE AND QUANTITYALL FUNCTIONS WIRE HOOK 8
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 2
TIME DELAYFIXED OPERATE TIME SECONDS MAXIMUM 0.015
TIME DELAYFIXED RELEASE TIME SECONDS MAXIMUM 0.015
ENVIRONMENTAL PROTECTIONHERMETIC
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY INCHES NOMINAL 1.437
OVERALL HEIGHTINCHES MAXIMUM 1.547
COIL QUANTITY1
WINDING DC RESISTANCE RATINGSINGLE WINDING OHMS NOMINAL 300.0
DUTY TYPECONTINUOUS
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS DC 25 DEG CELSIUS 26.5
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES DC 10.0
WINDING QUANTITY1
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY UNTHREADED HOLE(S) 2
MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY IN-LINE
UNTHREADED MOUNTING HOLE DIAMETERSINGLE MOUNTING FACILITY INCHES NOMINAL 0.144

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WB01WB01-FEB-05WB81WB
WP01WP01-JUN-11WP81WP
YA01YA01-DEC-99YA81YA
WU01WU01-OCT-16WU81WU
YB01YB01-APR-91YB81YB
YD01YD01-SEP-16YD81YD
YW01YW01-APR-91YW81YW
ZA01ZA01-APR-91ZA81ZA
ZC01ZC01-APR-91ZC81ZC
ZH01ZH01-APR-91ZH81ZH
ZI01ZI01-APR-19ZI81ZI
ZJ01ZJ01-MAR-25ZJ81ZJ
ZP01ZP01-APR-91ZP81ZP
ZR01ZR01-JUL-97ZR81ZR
ZT01ZT01-APR-91ZT81ZT
ZS01ZS01-APR-91ZS81ZS
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
A918DA1L01-APR-06ZCDGX01CD5DCD GXCLA196
C911GP1L01-APR-06GX01XG5DXG GXC007
FXGXDF1L01-APR-06ZSXGX01SX5DGX TUFXTX
N9BNDN1L01-APR-06ZKEGX01GH5DGXKE HD GT JBN9ND
VJ01VJ01-FEB-19VJ81VJ

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
QA
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
KE
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
BG
A-A-1898, Grade II, water resistant cellulosic cushioning
THK
C
3/4 inch thick
Unit cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0170
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
99174

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
21-MAR-1968
NIIN status code
0

Request a quote