Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
00NCB code
189-4397Item number
NIIN 00-189-4397
Request a quote
Unit price
$331.73
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
18-MAR-73
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8536490050

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$331.731U0NSF9EH-V$0.00F
01-OCT-2026DNJSMSEA0.0000$331.731U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$331.731U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
B07D992BA2-012277569
NORTH AMERICAN PHILIPS CORP
AC15TX3D
FC215-51278290
STRUTHERS-DUNN INC
HC15TX3B
M5757/23-01281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22ETX4D
MIL-DTL-5757/2381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
M5757/23-1281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC13ZZAC
MIL-R-5757/2381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETXB
2T2911-1202289
HI-G CO INC SUB OF NYTRONICS INC
HC15TX3D

Characteristics

ARC QUENCHING METHODAIR
MOUNTING SLOT WIDTHSINGLE MOUNTING FACILITY INCHES NOMINAL 0.150
ENVIRONMENTAL PROTECTIONHERMETIC
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
CUBIC MEASURECUBIC INCHES 1.763
MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY IN-LINE
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 2
TIME DELAYFIXED OPERATE AND RELEASE TIME SECONDS MAXIMUM 0.015
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS DC 25 DEG CELSIUS 6.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGELAMP LOAD MILLIAMPERES AC 800.0 AND AMPERES DC 1.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEMOTOR LOAD AMPERES AC 3.0 AND AMPERES DC 3.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 5.0 AND AMPERES DC 10.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0 AND DC 28.0
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-5757
TERMINAL TYPE AND QUANTITYALL FUNCTIONS WIRE HOOK 8
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-R-5757 TO 23
PURPOSE FOR WHICH DESIGNEDGENERAL
COIL QUANTITY1
OVERALL WIDTHINCHES MAXIMUM 0.625
OVERALL HEIGHTINCHES MAXIMUM 1.612
FRAGILITY FACTORMODERATELY RUGGED
WINDING QUANTITY1
OVERALL LENGTHINCHES MAXIMUM 1.750
WINDING DC RESISTANCE RATINGSINGLE WINDING OHMS MINIMUM 14.0 AND OHMS MAXIMUM 21.0
DUTY TYPECONTINUOUS
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY SLOTTED HOLE 2
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY INCHES NOMINAL 1.406

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-JUL-06WP81WP
ZC01ZC01-APR-91ZC81ZC
ZH01ZH01-APR-91ZH81ZH
FXGXDF1T01-NOV-05ZSXGX01SX5DGX TUFXTX
N9BNDN1T01-NOV-05ZGHGX01GH5DGXKEN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
01-DEC-1974
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.