Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
00NCB code
259-5676Item number
NIIN 00-259-5676
Request a quote
Unit price
$318.07
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
S
Hazardous material indicator
N
Schedule B export code
8536490050

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$318.071U0NSF9EH-V$0.00F
01-OCT-2026DSJSMSEA0.0000$318.071U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
167994-137695
RAYTHEON COMPANY
A325TX3D
MH401677342
TE CONNECTIVITY CORPORATION
A516TX3D
MH5846-177342
TE CONNECTIVITY CORPORATION
A595TX3D
5424-72HS82415
AIRPAX CORPORATION LLC DBA AIRPAX CORPORATION LLC
A59ETX3B

Characteristics

STORAGE TYPEGENERAL PURPOSE WAREHOUSE
THREAD DIRECTIONSINGLE MOUNTING FACILITY RIGHT-HAND
OVERALL HEIGHTINCHES MAXIMUM 1.921
TIME DELAYFIXED OPERATE TIME SECONDS MAXIMUM 0.015
TIME DELAYFIXED RELEASE TIME SECONDS MAXIMUM 0.01
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLESINGLE MOUNTING FACILITY INCHES NOMINAL 1.000
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS DC 25 DEG CELSIUS 13.2
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEINDUCTIVE LOAD AMPERES AC 3.0 AND AMPERES DC 1.5
CUBIC MEASURECUBIC INCHES 2.460
THREAD CLASS2A
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY THREADED STUD(S) 3
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0 AND DC 26.5
MATERIALCONTACT SILVER
PRECIOUS MATERIAL AND LOCATIONSILVER CONTACTS
PRECIOUS MATERIALSILVER
THREAD QUANTITY PER INCH40
NOMINAL THREAD SIZESINGLE MOUNTING FACILITY INCHES 0.112
MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY TRIANGLE
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 4
COIL QUANTITY1
WINDING DC RESISTANCE RATINGSINGLE WINDING OHMS NOMINAL 245.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 3.0 AND AMPERES DC 3.0
WINDING QUANTITY1
PURPOSE FOR WHICH DESIGNEDGENERAL
FRAGILITY FACTORMODERATELY RUGGED
OVERALL WIDTHINCHES MAXIMUM 0.953
THREAD SERIES DESIGNATORSINGLE MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYALL FUNCTIONS WIRE HOOK 14
ENVIRONMENTAL PROTECTIONHERMETIC
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY INCHES NOMINAL 0.500
OVERALL LENGTHINCHES MAXIMUM 1.344

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
WB01WB01-FEB-05WB81WB
YB01YB01-APR-91YB81YB
YW01YW01-APR-91YW81YW
ZC01ZC01-APR-91ZC81ZC
ZH01ZH01-APR-91ZH81ZH
ZR01ZR01-APR-91ZR81ZR
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-NOV-05ZW81ZW
FXGXDF1G01-NOV-05ZSXGX01SX5DGX TUFXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.3000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0170
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
95046

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
28-MAR-1971
NIIN status code
0

Request a quote