Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
00NCB code
534-7815Item number
NIIN 00-534-7815
Request a quote
Unit price
$25.04
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
11-SEP-74
Precious metals indicator
S
Hazardous material indicator
N
Schedule B export code
8536490050

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$25.041U0AQ2200X-$0.00A
01-OCT-2026DFZSMSEA0.0000$25.041U0NSF9EH-N$0.00F
01-OCT-2026DNZSMSEA0.0000$25.041U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$25.041U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
KU50A41-12077342
TE CONNECTIVITY CORPORATION
A52ETXD
SK2-129582415
AIRPAX CORPORATION LLC DBA AIRPAX CORPORATION LLC
A59BTXB
12A99A115-005482415
AIRPAX CORPORATION LLC DBA AIRPAX CORPORATION LLC
A595TXB
157-10T1A304221
MIDLAND-ROSS CORP MIDTEX DIV
H395TA3D

Characteristics

THREAD CLASS2B
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION 1 AND POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION 1
TIME DELAYFIXED OPERATE TIME SECONDS NOMINAL 0.015
TIME DELAYFIXED RELEASE TIME SECONDS NOMINAL 0.01
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS AC 25 DEG CELSIUS 120.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 5.0 AND AMPERES DC 5.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 240.0 AND DC 28.0
MATERIALCONTACT SILVER
PRECIOUS MATERIAL AND LOCATIONSILVER CONTACTS
PROPRIETARY CHARACTERISTICSPACS
THREAD DIRECTIONSINGLE MOUNTING FACILITY RIGHT-HAND
OVERALL LENGTHINCHES MAXIMUM 1.680
OVERALL HEIGHTINCHES MAXIMUM 1.687
OVERALL WIDTHINCHES MAXIMUM 1.468
FRAGILITY FACTORMODERATELY RUGGED
FREQUENCY IN HERTZMINIMUM 50.0 AND MAXIMUM 60.0
WINDING QUANTITY1
PURPOSE FOR WHICH DESIGNEDGENERAL
THREAD QUANTITY PER INCH32
NOMINAL THREAD SIZESINGLE MOUNTING FACILITY INCHES 0.138
ARC QUENCHING METHODAIR
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY THREADED HOLE(S) 1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
CUBIC MEASURECUBIC INCHES 4.160
WINDING DC RESISTANCE RATINGSINGLE WINDING KILOHMS NOMINAL 2.250
DUTY TYPECONTINUOUS
TERMINAL TYPE AND QUANTITYALL FUNCTIONS TAB, SOLDER LUG 6
COIL QUANTITY1
THREAD SERIES DESIGNATORSINGLE MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC)

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-OCT-06WP81WP
A918DA3C01-APR-06ZCDGX01CD5DCD GXAZ CLA196
FXGXDF3C01-APR-06ZSXGX01SX5DGX TUFXTX
N9BNDN3C01-APR-06ZGHGX01GH5DGXN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
JA
A-A-3174, plastic sheet, polyolefin, 2 mil
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.2000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0240
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
13-NOV-1981
NIIN status code
0

Request a quote