Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
00NCB code
547-8738Item number
NIIN 00-547-8738
Request a quote
Unit price
$3,517.06
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8536490075

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$3,517.061U0ZQ2200X-$0.00A
01-OCT-2026DFZSMSEA0.0000$3,517.061U0NSF9---N$0.00F
01-OCT-2026DMZSMSEA0.0000$3,517.061U0Z15B2---$0.00M
01-OCT-2026DNZSMSEA0.0000$3,517.061U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$3,517.061U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MIL-R-610681349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETX4B
MIL-PRF-610681349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59EZZ4B
6042H153-381640
SAFRAN POWER USA, LLC
A3254D
MS24184-D196906
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETX4B

Characteristics

MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY IN-LINE
COIL QUANTITY1
CUBIC MEASURECUBIC INCHES 44.646
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY UNTHREADED HOLE(S) 2
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
WINDING DC RESISTANCE RATINGSINGLE WINDING OHMS NOMINAL 52.0
DUTY TYPECONTINUOUS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY INCHES NOMINAL 3.000
OVERALL HEIGHTINCHES MAXIMUM 3.700
OVERALL WIDTHINCHES MAXIMUM 3.315
SPECIFICATION/STANDARD DATAGOVERNMENT STANDARD 96906--S24184
OVERALL LENGTHINCHES MAXIMUM 3.640
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS DC 25 DEG CELSIUS 28.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEINDUCTIVE LOAD AMPERES DC 100.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEMOTOR LOAD AMPERES DC 250.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 300.0 AND AMPERES DC 300.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0 AND DC 28.0
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-6106
TERMINAL TYPE AND QUANTITYALL FUNCTIONS THREADED STUD 4
TIME DELAYFIXED OPERATE TIME SECONDS MAXIMUM 0.035
TIME DELAYFIXED RELEASE TIME SECONDS MAXIMUM 0.015
ARC QUENCHING METHODAIR
ENVIRONMENTAL PROTECTIONHERMETIC
UNTHREADED MOUNTING HOLE DIAMETERSINGLE MOUNTING FACILITY INCHES NOMINAL 0.266
FRAGILITY FACTORMODERATELY RUGGED
WINDING QUANTITY1
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION 1
PURPOSE FOR WHICH DESIGNEDGENERAL

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WG01WG01-OCT-17WG81WG
YC01YC01-MAY-21YC81YC
YD01YD01-SEP-16YD81YD
YW01YW01-MAY-21YW81YW
YR01YR01-AUG-24YR81YR
YJ01YJ01-APR-91YJ81YJ
ZC01ZC01-APR-91ZC81ZC
ZJ01ZJ01-MAR-25ZJ81ZJ
ZR01ZR01-JUL-97ZR81ZR
A918DA4D01-NOV-05ZCDGX01CD5DCD GXCT BDA196
FXGXDF4D01-NOV-05ZSXGX01SX5DGX TUFXTX
MC49DM4D01-OCT-09ZPAGX01PA5DGX PA
N9BNDN4D01-NOV-05ZGHGX01GH5DGXHD GTN9ND

Management phrases

Major organizational entity
DF
USC
F
Phrase code
R
Phrase
REFER TO APPROVED FOR FAA USE
Quantity per assembly
0
Technical document
APPROVED FOR FAA USE

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
PVC
N
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
03Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
E5
ASTM D5118/D5118M, fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
2.5000
UP SZ MAXB
3.30000
UP SZ MAXL
3.60000
UP SZ MAXH
3.70000
Unit pack cube
0.0250
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
9T
Dt stdzn dec
08-OCT-1965
NIIN status code
0

Cancelled and replaced NIINs

FSC
5945
Cancelled NIIN
5945-01-290-7459
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.