Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
00NCB code
866-1931Item number
NIIN 00-866-1931
Request a quote
Unit price
$24.16
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
19-OCT-72
Precious metals indicator
S
Hazardous material indicator
N
Schedule B export code
8536490075
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$24.161U0AQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$24.161U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$24.161U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
KRP5AG24V77342
TE CONNECTIVITY CORPORATION
A59ETX3B
KRPA5AG-2477342
TE CONNECTIVITY CORPORATION
A32EZZ
KRPA5AG-24VAC77342
TE CONNECTIVITY CORPORATION
A59ETX

Characteristics

NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 1
NOMINAL OPERATING CURRENT RATING AND TYPESINGLE WINDING MILLIAMPERES AC 84.0
TIME DELAYFIXED OPERATE TIME SECONDS NOMINAL 0.015
TIME DELAYFIXED RELEASE TIME SECONDS NOMINAL 0.01
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS AC 25 DEG CELSIUS 24.0
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
OVERALL LENGTHINCHES MAXIMUM 1.406
OVERALL WIDTHINCHES MAXIMUM 1.406
ENVIRONMENTAL PROTECTIONDUSTPROOF
FRAGILITY FACTORMODERATELY RUGGED
FREQUENCY IN HERTZMINIMUM 50.0 AND MAXIMUM 60.0
WINDING QUANTITY1
COIL QUANTITY1
WINDING DC RESISTANCE RATINGSINGLE WINDING OHMS NOMINAL 85.0
DUTY TYPECONTINUOUS
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY PLUG-IN TERMINAL(S) 1
PRECIOUS MATERIALSILVER
TERMINAL TYPE AND QUANTITYALL FUNCTIONS STANDARD TUBE BASE 1
MATERIALCASE PLASTIC
MATERIALCONTACT SILVER
PRECIOUS MATERIAL AND LOCATIONSILVER CONTACTS
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 10.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 120.0 AND DC 28.0
ENERGIZING ELEMENT POWER RATINGVOLTS-AMPERES 2.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabFmr MOE rl
A918DA3L01-NOV-05ZCDGX01CD5DCD GXA196
FXGXDF3L01-NOV-05ZSXGX01SX5DGX TUFXTX
G860T10001-APR-91C864875 86

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
EA
MIL-DTL-17667, neutral wrapping paper
Cush dun
DA
A-A-1051, paperboard cushioning
THK
C
3/4 inch thick
Unit cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
21189

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
01-DEC-1974
NIIN status code
0

Cancelled and replaced NIINs

FSC
5945
Cancelled NIIN
5945-01-267-3959
NIIN status code
7
Effective date
02-JUL-2026
DEMIL code
A

Request a quote