Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
00NCB code
902-9015Item number
NIIN 00-902-9015
Request a quote
Unit price
$156.53
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-60
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8536490050
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$156.531U0NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$156.531U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$156.531U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
271-1003P33B150
RAYTHEON COMPANY DBA RAYTHEON CO
A321TX
271-1003P00349956
RAYTHEON COMPANY DIV CORP
AC15ZZAC
271-1003P349956
RAYTHEON COMPANY DIV CORP
A591TX3B
271-1003P354X10
RAYTHEON COMPANY
A525ZZ
PS101877342
TE CONNECTIVITY CORPORATION
A515TX3D
B0T6A115VAC02288
ALLIED CONTROLS, INC.
A595TX1B
BOT6A120VAC02288
ALLIED CONTROLS, INC.
A523TX1D
7489014P108771
GENERAL ELECTRIC CO MOBILE COMMUNICATIONS BUSINESS DIV
A525TX1D

Characteristics

WINDING QUANTITY1
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY THREADED HOLE(S) 4
WINDING DC RESISTANCE RATINGSINGLE WINDING OHMS NOMINAL 445.0
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
COIL QUANTITY1
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY INCHES NOMINAL 0.500
OVERALL LENGTHINCHES MAXIMUM 1.938
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY INCHES NOMINAL 1.312
THREAD CLASS2B
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS AC 25 DEG CELSIUS 120.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 6.0 AND AMPERES DC 6.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0 AND DC 29.0
THREAD SERIES DESIGNATORSINGLE MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYALL FUNCTIONS PIN 8
OVERALL HEIGHTINCHES MAXIMUM 1.500
OVERALL WIDTHINCHES NOMINAL 1.625
FREQUENCY IN HERTZNOMINAL 60.0
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 2
TIME DELAYFIXED OPERATE TIME SECONDS NOMINAL 0.03
TIME DELAYFIXED RELEASE TIME SECONDS NOMINAL 0.01
MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY RECTANGULAR
NOMINAL THREAD SIZESINGLE MOUNTING FACILITY INCHES 0.138

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
FXGXDF1R01-JUL-05ZSXGX01SX5DGX TUFXTX
G930T10001-APR-91C934875 93
N9BNDN1R01-JUL-05ZGHGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
1.60000
UP SZ MAXL
1.90000
UP SZ MAXH
1.50000
Unit pack cube
0.0020
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
28-MAR-1971
NIIN status code
0

Cancelled and replaced NIINs

FSC
5960
Cancelled NIIN
5960-00-071-7346
NIIN status code
7
Effective date
01-JUL-2026
DEMIL code
A

Request a quote