Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
01NCB code
040-8958Item number
NIIN 01-040-8958
Request a quote
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
12-MAY-77
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8536490050
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCRNJC
MIL-PRF-39016/681349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
MILR39016-681349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETX1B
M39016/6-20981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX4B
M39016/6-109M81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX4D4
93220301-08M99699
DRI RELAYS INC. DBA DRI RELAYS INC
AC15TX4D
10317370A486G
NIMIKKEISTOKESKUS NCB FINLAND
A699WF4B
ERS6A1-26-5M102288
ALLIED CONTROLS, INC.
AC16TX4D
3SAV1959A201526
GENICOM CORP
HC15TX4D

Characteristics

OVERALL LENGTHINCHES MAXIMUM 0.810
OVERALL HEIGHTINCHES MAXIMUM 0.617
OVERALL WIDTHINCHES MAXIMUM 0.410
ENVIRONMENTAL PROTECTIONHERMETIC
WINDING QUANTITY1
COIL QUANTITY1
WINDING DC RESISTANCE RATINGSINGLE WINDING OHMS NOMINAL 700.0
DUTY TYPECONTINUOUS
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY PLUG-IN TERMINAL(S) 1
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 2
TIME DELAYFIXED OPERATE AND RELEASE TIME SECONDS MAXIMUM 0.004
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS DC 25 DEG CELSIUS 26.5
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD MILLIAMPERES AC 300.0 AND AMPERES DC 2.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0 AND DC 28.0
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-39016
TERMINAL TYPE AND QUANTITYALL FUNCTIONS PIN 8
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-R-39016 TO 6

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedAcquisition advice codePICAPICA LOAAuth collab
WF01WF01-JUN-11WF81WF
WB01WB01-FEB-05WB81WB
VJ01VJ01-MAR-19VJ81VJ
YA01YA01-DEC-01YA81YA
YB01YB01-APR-91YB81YB
YC01YC01-MAY-21YC81YC
YD01YD01-SEP-16YD81YD
YS01YS01-FEB-15YS81YS
YJ01YJ01-APR-91YJ81YJ
YW01YW01-AUG-97YW81YW
ZB01ZB01-APR-91ZB81ZB
ZE01ZE01-APR-91ZE81ZE
ZC01ZC01-APR-91ZC81ZC
ZG01ZG01-APR-91ZG81ZG
ZF01ZF01-APR-91ZF81ZF
ZH01ZH01-APR-91ZH81ZH
ZJ01ZJ01-APR-25ZJ81ZJ
ZN01ZN01-APR-91ZN81ZN
ZK01ZK01-APR-91ZK81ZK
ZP01ZP01-APR-91ZP81ZP
ZR01ZR01-APR-91ZR81ZR
ZT01ZT01-DEC-23ZT81ZT
ZS01ZS01-APR-91ZS81ZS
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-DEC-95ZW81ZW
ZX01ZX01-APR-91ZX81
G170T10001-APR-91C174817 75

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
60Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
AA
THK
X
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
A

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
HERMETICALLY SEALED

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
07-JAN-1985
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59455945-00-378-0414502-JUL-2026A
59455945-00-115-8336502-JUL-2026A
59455945-00-022-8159502-JUL-2026A
59455945-00-166-3437502-JUL-2026A
59455945-00-912-8755502-JUL-2026A
49354935-01-031-2616502-JUL-2026B
59455945-00-930-4149502-JUL-2026A
59455945-00-904-8563502-JUL-2026A
59455945-01-029-2199502-JUL-2026A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.