Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
01NCB code
155-5534Item number
NIIN 01-155-5534
Request a quote
Unit price
$1,449.02
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
10-JUN-83
Precious metals indicator
G
Hazardous material indicator
N
Schedule B export code
8536490075

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNZSMSEA0.0000$1,449.021U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$1,449.021U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACSADC
7022L81N3L514
SOUTHERN PACIFIC PIPE LINE INC
AC16ZZAC
551-7610107-00753711
NAVAL SEA SYSTEMS COMMAND
AC15ZZAC
7022L8IN89020
TE CONNECTIVITY CORPORATION
A32ETX
1-1423163-989020
TE CONNECTIVITY CORPORATION
A323ZZ
H761-0107-00796169
ELECTRIC BOAT CORPORATION DIV GENERAL DYNAMICS ELECTRIC BOAT
AC15ZZAC

Characteristics

THREAD CLASS2B
THREAD DIRECTIONSECOND MOUNTING FACILITY RIGHT-HAND
OVERALL LENGTHINCHES MAXIMUM 3.250
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHFIRST MOUNTING FACILITY INCHES NOMINAL 2.880
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSECOND MOUNTING FACILITY INCHES NOMINAL 1.750
OVERALL HEIGHTINCHES MAXIMUM 4.520
OVERALL WIDTHINCHES MAXIMUM 3.090
ENVIRONMENTAL PROTECTIONDUSTPROOF
UNTHREADED MOUNTING HOLE DIAMETERFIRST MOUNTING FACILITY INCHES NOMINAL 0.199
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHTSECOND MOUNTING FACILITY INCHES NOMINAL 0.500
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHTFIRST MOUNTING FACILITY INCHES MINIMUM 0.750 AND INCHES MAXIMUM 1.500
FRAGILITY FACTORMODERATELY RUGGED
FREQUENCY IN HERTZNOMINAL 60.0
WINDING QUANTITY1
PURPOSE FOR WHICH DESIGNEDGENERAL
COIL QUANTITY1
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
MOUNTING FACILITY TYPE AND QUANTITYSECOND MOUNTING FACILITY THREADED HOLE(S) 4
MOUNTING FACILITY TYPE AND QUANTITYFIRST MOUNTING FACILITY UNTHREADED HOLE(S) 6
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
CUBIC MEASURECUBIC INCHES 45.392
THREAD QUANTITY PER INCH32
NOMINAL THREAD SIZESECOND MOUNTING FACILITY INCHES 0.164
MOUNTING FACILITY PATTERNSECOND MOUNTING FACILITY RECTANGULAR
MOUNTING FACILITY PATTERNFIRST MOUNTING FACILITY RECTANGULAR
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 2
TIME DELAYADJUSTABLE RELEASE TIME MINUTES MINIMUM 6.00 AND MINUTES MAXIMUM 60.00
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS AC 25 DEG CELSIUS 110.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 15.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 240.0 AND DC 30.0
ENERGIZING ELEMENT POWER RATINGWATTS 8.0
MATERIALCONTACT GOLD
MATERIALCASE PLASTIC
PRECIOUS MATERIAL AND LOCATIONGOLD CONTACTS
PRECIOUS MATERIALGOLD
THREAD SERIES DESIGNATORSECOND MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYALL FUNCTIONS SCREW 8

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZC01ZC01-APR-91ZC81ZC
N9BNDN3C01-APR-06ZHDGX01GH5DGXGT HDN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
2.3000
UP SZ MAXB
4.00000
UP SZ MAXL
3.30000
UP SZ MAXH
4.40000
Unit pack cube
0.0330
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
10-JUN-1983
NIIN status code
0

Request a quote