Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
01NCB code
280-2186Item number
NIIN 01-280-2186
Request a quote
Unit price
$317.41
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
Y
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
03-JUN-88
Precious metals indicator
A
Hazardous material indicator
N
Schedule B export code
8536490050
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$317.411U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$317.411U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSCSADC
M39016/21-045P81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22ETX
MIL-R-39016/2181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETXB
MIL-PRF-39016/2181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A414ZZ
432DM-1811532
TELEDYNE DEFENSE ELECTRONICS, LLC DBA TELEDYNE RELAYS DIV HTTPS://WWW.TELEDYNE.COM/WHAT-WE-DO/
AC16ZZAC

Characteristics

OVERALL LENGTHINCHES MAXIMUM 0.370
OVERALL HEIGHTINCHES MAXIMUM 0.493
OVERALL WIDTHINCHES MINIMUM 0.332 AND INCHES MAXIMUM 0.338
ENVIRONMENTAL PROTECTIONDUSTPROOF
WINDING QUANTITY1
PURPOSE FOR WHICH DESIGNEDGENERAL
COIL QUANTITY1
WINDING DC RESISTANCE RATINGSINGLE WINDING OHMS MAXIMUM 0.1
DUTY TYPECONTINUOUS
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY PLUG-IN TERMINAL(S) 1
CUBIC MEASURECUBIC INCHES 0.062
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 2
CRITICALITY CODE JUSTIFICATIONFEAT
TIME DELAYFIXED RELEASE TIME SECONDS MAXIMUM 0.008
TIME DELAYFIXED OPERATE TIME SECONDS MAXIMUM 0.004
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS DC 25 DEG CELSIUS 18.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEINDUCTIVE LOAD AMPERES DC 0.2
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGELAMP LOAD AMPERES DC 0.1
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES DC 1.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0 AND DC 28.0
SPECIAL FEATURESCONTAINS A FAILURE RATE OF 0.100
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-39016
TERMINAL TYPE AND QUANTITYALL FUNCTIONS PIN 8
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-R-39016 TO 21

MOE rules

MOE rule
FXGX
MOE CD
DF
AMC
1
AMSC
T
Date assigned
01-NOV-05
IMC
Z
IMCA
SX
PICA
GX
PICA LOA
01
SICA
SX
SICA LOA
5D
Auth collab
GX TU
Fmr MOE rl
FXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
TX
Dt stdzn dec
01-JAN-2000
NIIN status code
0

Cancelled and replaced NIINs

FSC
5945
Cancelled NIIN
5945-01-052-9543
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote