Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
01NCB code
281-2257Item number
NIIN 01-281-2257
Request a quote
Unit price
$831.11
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
19-JUN-88
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8536490075

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFZSMSEA0.0000$831.111U0NSF9EH-N$0.00F
01-OCT-2026DNZSMSEA0.0000$831.111U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$831.111U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
M6106/13-00581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22ETX
MIL-PRF-6106/1381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
MIL-R-6106/1381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETXB
10132680A486G
NIMIKKEISTOKESKUS NCB FINLAND
A699WF4B

Characteristics

OVERALL LENGTHINCHES MAXIMUM 1.025
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY INCHES NOMINAL 0.625
OVERALL HEIGHTINCHES MAXIMUM 1.010
OVERALL WIDTHINCHES MAXIMUM 1.025
MOUNTING SLOT WIDTHSINGLE MOUNTING FACILITY INCHES NOMINAL 0.150
ENVIRONMENTAL PROTECTIONHERMETIC
FRAGILITY FACTORMODERATELY RUGGED
WINDING QUANTITY1
PURPOSE FOR WHICH DESIGNEDGENERAL
COIL QUANTITY1
DUTY TYPECONTINUOUS
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY SLOTTED HOLE 3
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
CUBIC MEASURECUBIC INCHES 1.061
MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY TRIANGLE
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION 3
TIME DELAYFIXED OPERATE AND RELEASE TIME SECONDS MAXIMUM 0.015
NONPILE-UP AUXILIARY CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 1
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0 AND DC 28.0
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLESINGLE MOUNTING FACILITY INCHES MINIMUM 1.396 AND INCHES MAXIMUM 1.446
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS DC 25 DEG CELSIUS 28.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEINDUCTIVE LOAD AMPERES DC 12.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEMOTOR LOAD AMPERES AC 10.0 AND AMPERES DC 10.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGELAMP LOAD AMPERES AC 5.0 AND AMPERES DC 5.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 25.0 AND AMPERES DC 25.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0 AND DC 28.0
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGELAMP LOAD MILLIAMPERES AC 500.0 AND MILLIAMPERES DC 500.0
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEINDUCTIVE LOAD AMPERES DC 1.0
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 2.0 AND AMPERES DC 2.0
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-6106
TERMINAL TYPE AND QUANTITYALL FUNCTIONS PIN 8
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-R-6106 TO 13

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WF01WF01-APR-11WF81WF
YB01YB01-JUN-99YB81YB
YD01YD01-AUG-17YD81YD
ZC01ZC01-APR-91ZC81ZC
ZR01ZR01-JUL-97ZR81ZR
FXGXDF1T01-APR-06ZSXGX01SX5DGX TUFXTX
N9BNDN1T01-APR-06ZGHGX01GH5DGXGT KEN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
A
1/4 inch thick
Unit cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.4000
UP SZ MAXB
1.00000
UP SZ MAXL
1.00000
UP SZ MAXH
1.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
1TX16-OCT-19890
3TX30-SEP-19890
5945-01-123-14303TX30-SEP-19890

Cancelled and replaced NIINs

FSC
5945
Cancelled NIIN
5945-01-230-9435
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote