Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
01NCB code
321-1883Item number
NIIN 01-321-1883
Request a quote
Unit price
$1,119.45
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
13-JUN-90
Precious metals indicator
A
Hazardous material indicator
N
Schedule B export code
8536490075

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$1,119.451U0ZQ2200X-$0.00A
01-OCT-2026DNZSMSEA0.0000$1,119.451U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$1,119.451U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
549392353711
NAVAL SEA SYSTEMS COMMAND
A32ATX
JSA-J2K-00658657
LEACH INTERNATIONAL CORP DIV LEACH INTERNATIONAL CORPORATION
A52AZZ
JSA-J2K58657
LEACH INTERNATIONAL CORP DIV LEACH INTERNATIONAL CORPORATION
A59EZZB
549392315090
RAYTHEON COMPANY
A525TX

Characteristics

OVERALL LENGTHINCHES MAXIMUM 1.770
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY INCHES MINIMUM 1.401 AND INCHES MAXIMUM 1.441
OVERALL HEIGHTINCHES MINIMUM 0.505 AND INCHES MAXIMUM 0.525
OVERALL WIDTHINCHES MAXIMUM 1.718
MOUNTING SLOT WIDTHSINGLE MOUNTING FACILITY INCHES MINIMUM 0.140 AND INCHES MAXIMUM 0.160
ENVIRONMENTAL PROTECTIONHERMETIC AND VIBRATION PROOF AND SHOCK PROOF
FRAGILITY FACTORMODERATELY RUGGED
END ITEM IDENTIFICATIONSTARTER MTR
FREQUENCY IN HERTZMINIMUM 50.0 AND MAXIMUM 400.0
WINDING QUANTITY1
PURPOSE FOR WHICH DESIGNEDGENERAL
COIL QUANTITY1
DUTY TYPECONTINUOUS
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY SLOTTED HOLE 2
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
CUBIC MEASURECUBIC INCHES 0.605
MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY IN-LINE
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 1
NOMINAL OPERATING CURRENT RATING AND TYPESINGLE WINDING MILLIAMPERES AC 24.0
TIME DELAYFIXED OPERATE TIME SECONDS MAXIMUM 0.015
TIME DELAYFIXED RELEASE TIME SECONDS MAXIMUM 0.05
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS AC 25 DEG CELSIUS 115.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 10.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGELAMP LOAD AMPERES AC 4.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEMOTOR LOAD AMPERES AC 8.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0
TERMINAL TYPE AND QUANTITYALL FUNCTIONS WIRE HOOK 5

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WG01WG01-OCT-17WG81WG
ZG01ZG01-APR-94ZG81ZG
A918DA1C01-MAR-17ZCLGX01CD5DCD GXCL
N9BNDN1C01-NOV-05ZHDGX01GH5DGXGT HDN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
60Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0150
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
13-JUN-1990
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.