Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
01NCB code
461-9953Item number
NIIN 01-461-9953
Request a quote
Unit price
$267.97
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
14-JAN-99
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
D
Schedule B export code
8536490075

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DADSMSEA0.0000$267.971U0ZQ22CCX-$0.00A
01-OCT-2026DFDSMSEA0.0000$267.971U0NSF9EH-N$0.00F
01-OCT-2026DNDSMSEA0.0000$267.971U09B-----$0.00N
01-OCT-2026DSDSMSEA0.0000$267.971U0N-------$0.00I
01-OCT-2026GPDSMSEA0.0000$267.971U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
MIL-PRF-83536/3381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
MIL-PRF-610681349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59EZZB
M83536/33-002L81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22EZZ
MS27743-1696906
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593ZZB

Characteristics

OVERALL LENGTHINCHES MAXIMUM 1.718
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY INCHES MINIMUM 1.396 AND INCHES MAXIMUM 1.446
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY INCHES NOMINAL 0.625
OVERALL HEIGHTINCHES MAXIMUM 1.010
OVERALL WIDTHINCHES MAXIMUM 1.025
MOUNTING SLOT WIDTHSINGLE MOUNTING FACILITY INCHES NOMINAL 0.150
WINDING QUANTITY1
PURPOSE FOR WHICH DESIGNEDGENERAL
COIL QUANTITY1
DUTY TYPECONTINUOUS
PILE-UP MAIN CONTACT FORM ARRANGEMENT3C
FEATURES PROVIDEDCOIL VOLTAGE SUPPRESSION
MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY TRIANGLE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLESINGLE MOUNTING FACILITY INCHES NOMINAL 0.312
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS DC 25 DEG CELSIUS 13.5
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGELAMP LOAD AMPERES AC 5.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEMOTOR LOAD AMPERES AC 10.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEINDUCTIVE LOAD AMPERES DC 12.0 AND AMPERES AC 15.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 25.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0 AND DC 28.0
SPECIAL FEATURES3PDT, 25 AMP (RESISTIVE), HERMETICALLY SEALED, 28 VDC COIL, 3% FAILURE RATE, RAISED VERTICAL FLANGE MOUNT, RELAY
TERMINAL TYPE AND QUANTITYCONTACTS WIRE HOOK 9

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WZ01WZ01-MAY-22WZ81WZ
YA01YA01-MAR-10YA81YA
YB01YB01-DEC-05YB81YB
ZA01ZA01-AUG-08ZA81ZA
ZG01ZG01-JAN-15ZG81ZG
ZH01ZH01-JUL-11ZH81ZH
ZJ01ZJ01-APR-25ZJ81ZJ
ZK01ZK01-JUL-23ZK81ZK
ZR01ZR01-DEC-07ZR81ZR
ZU01ZU01-JUL-05ZU81ZU
A918DA1T01-NOV-05ZCTGX01CD5DCD GXCTA196
C911GP1T01-NOV-05GX01XG5DXG GXXHC007
FXGXDF1T01-NOV-05ZSXGX01SX5DGX TUFXTX
N9BNDN1T01-NOV-05ZHDGX01GH5DGXJB KE HD GTN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
CC
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
B
1/2 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.2000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0050
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
ETX21-JAN-19990
BTX21-JAN-19990
5945-01-169-4123ETX21-JAN-19990
5945-01-190-4683ETX21-JAN-19990

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.