Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
005-8903Item number
NIIN 00-005-8903
Request a quote
Unit price
$254.53
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
19-JUN-72
Precious metals indicator
U
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$254.531U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$254.531U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
318466959364
HONEYWELL INTERNATIONAL INC. DBA HONEYWELL INTERNATIONAL
A325ZZ
318466977068
ALLIED-SIGNAL INC DBA ALLIED-SIGNAL AEROSPACE CO ELECTRODYNAMICS DIV
R39ATX3D
E-29009798
PAYNE MAGNETICS, INC.
A525TX4D

Characteristics

BODY LENGTHINCHES MAXIMUM 1.500
TERMINAL TYPE AND QUANTITYWIRE LEAD 13
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 0.3
BODY WIDTHINCHES MAXIMUM 1.250
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 6.00
WINDING POWER RATINGSINGLE COMPONENT FOURTH SECONDARY MILLIWATTS 140.0
BODY HEIGHTINCHES MAXIMUM 1.250
MAXIMUM OPERATING TEMPCELSIUS 75.0
DISTANCE BETWEEN MOUNTING FACILITY CENTERSSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.750
INCLOSURE TYPEFULLY INCLOSED
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 12.80
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC MAXIMUM 6.0
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 0.2
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 4
WINDING POWER RATINGSINGLE COMPONENT SECOND SECONDARY WATTS 3.2
WINDING POWER RATINGSINGLE COMPONENT THIRD SECONDARY MILLIWATTS 70.0
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 48.00
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 24.40
MOUNTING FACILITY QUANTITY2
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 12.0
WINDING POWER RATINGSINGLE COMPONENT FIRST SECONDARY WATTS 7.2
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00
FEATURES PROVIDEDCOLOR CODED LEAD
MOUNTING METHODSINGLE GROUP FLANGE AND UNTHREADED HOLE(S)
MOUNTING HOLE DIAMETERSINGLE GROUP INCHES MINIMUM 0.120 AND INCHES MAXIMUM 0.140

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-DEC-99YA81YA
YB01YB01-FEB-94YB81YB
ZC01ZC01-APR-91ZC81ZC
ZR01ZR01-JUL-97ZR81ZR
ZU01ZU01-JUL-05ZU81ZU
ZW01ZW01-NOV-05ZW81ZW
N9BNDN1G01-JUN-06ZGHGX01GH5DGXKEN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
60Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.3000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
24-JUN-1972
NIIN status code
0

Request a quote