Catalog item
Request a quoteTRANSFORMER,POWER
5950FSC
00NCB code
024-3765Item number
NIIN 00-024-3765
- Unit price
- $2,306.41
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 32496
- PINC
- 0032496
- Criticality code
- X
- II
- M
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 17-OCT-72
- Precious metals indicator
- U
- Hazardous material indicator
- P
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DF | J | SMS | EA | 0.0000 | $2,306.41 | 1 | U | 0 | N | SF9EH-N | $0.00 | F |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $2,306.41 | 1 | U | 0 | N | ------- | $0.00 | I |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| 44356 | 73386 FREED TRANSFORMER CO | A | 5 | 2 | 5 | TX | ||
| BX-9386 | 85323 BALTIMORE TRANSFORMER CO | A | 5 | 2 | 5 | TX | ||
| 666693-1 | 95266 OECO, LLC DBA PACIFIC SCIENTIFIC OECO DIV FIRE SAFETY AND POWER SYSTEMS | A | 5 | 2 | 5 | ZZ | ||
| 666693-1 | 96214 RAYTHEON COMPANY DBA RAYTHEON | A | 3 | 2 | 5 | 48 | 3 | D |
| 666693-1 | 0VCT0 SUPERIOR MAGNETICS | R | 5 | 9 | 5 | ZZ | B |
Characteristics
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 260.00 |
|---|---|
| NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.138 |
| TERMINAL TYPE AND QUANTITY | WIRE LOOP 6 |
| WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| THREAD QUANTITY PER INCH | 32 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.750 |
| THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| BODY HEIGHT | INCHES NOMINAL 3.750 |
| TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-T-27 |
| MOUNTING FACILITY QUANTITY | 4 |
| MOUNTING METHOD | SINGLE GROUP THREADED STUD(S) |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.125 |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE |
| WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES AC MAXIMUM 32.0 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 208.00 |
| BODY LENGTH | INCHES NOMINAL 2.719 |
| BODY WIDTH | INCHES NOMINAL 2.313 |
| FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 60.0 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YA01 | YA | 01-JAN-11 | YA | 81 | YA | |||||||
| ZT01 | ZT | 01-JAN-99 | ZT | 81 | ZT | |||||||
| FXGX | DF | 1 | H | 01-JUN-06 | Z | SX | GX | 01 | SX | 5D | GX TU | FXTX |
Service data
Air Force
- Fund
- SF
- Budget
- 9
- MMAC
- EH
- PVC
- N
- ERRC
- N
Freight
- ACTY CD
- 48
- NMFC
- 063420
- NMFC sub
- Z
- Uniform freight class
- 35355
- Less than truckload
- W
- Water commodity code
- 595
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- TRANSFORMERS,NOI,OR TRANSFORMER PAR
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 10Physical protection
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- JCASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
- THK
- C3/4 inch thick
- Unit cont
- ECASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- DOAny suitable fiber box included in this table may be used (see J.4.9.1).
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- UItems or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
- Unit pack weight
- 2.7000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0010
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 05-NOV-1972
- NIIN status code
- 0
Request a quote