Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
059-4816Item number
NIIN 00-059-4816
Request a quote
Unit price
$185.57
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
M
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-61
Precious metals indicator
U
Hazardous material indicator
P

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
Y
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$185.57
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
T662905853
PTC TRANSFORMERS
H59XXX3B
27-129-6205853
PTC TRANSFORMERS
H595HD3B
102968REVA06231
GOULD INC INDUSTRIAL BATTERY DIV
H39XXX3D

Characteristics

BODY WIDTHINCHES MAXIMUM 2.625
THREAD QUANTITY PER INCH32
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.164
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 50.0
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC MAXIMUM 255.0
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 50.0
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 255.0
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 72.00
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 348.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 72.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 348.00
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 4
BODY HEIGHTINCHES MAXIMUM 4.250
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED STUD(S)
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.297
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.859
OVERALL HEIGHTINCHES NOMINAL 4.625
FREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 380.0 AND HERTZ MAXIMUM 420.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE
BODY LENGTHINCHES MAXIMUM 3.062
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYWIRE HOOK 12

MOE rules

MOE rule
DGX1
MOE CD
DS
AMC
3
AMSC
C
Date assigned
01-JUN-06
PICA
GX
PICA LOA
01
Auth collab
GX
Supp collab
TX
Fmr MOE rl
DTX1

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
13-JAN-1968
NIIN status code
0

Cancelled and replaced NIINs

FSC
5950
Cancelled NIIN
5950-00-497-9217
NIIN status code
7
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.