Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
155-1029Item number
NIIN 00-155-1029
Request a quote
Unit price
$549.67
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
22-OCT-71
Precious metals indicator
A
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAXSMSEA0.0000$549.671U0ZQ2200X-$0.00A
01-OCT-2026DSXSMSEA0.0000$549.671U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
4107022558
COAST/ADVANCED CHIP MAGNETICS, INC.
A525TX
NE894594315
NEW ENGLAND TRANSFORMER CO INC
H396BD1D
5950001551029A00AM
E.C.A ETABLISSEMENT CENTRAL DES APPROVISIONNEMENTS DES FORCES ARMEES ROYALES
A699YP4B
TT742311850
MAGNETIKA/EAST LTD TITAN TRANSFORMER DIV
H595TXB
SAFA-10-A11850
MAGNETIKA/EAST LTD TITAN TRANSFORMER DIV
H596BD1B
1067968518876
US ARMY AVIATION AND MISSILE COMMAND
A72ATX1D

Characteristics

THREAD QUANTITY PER INCH32
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.138
WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE PRIMARY MILLIAMPERES AC MAXIMUM 450.0
WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES AC MAXIMUM 2.0
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS MINIMUM 105.00 AND AC VOLTS MAXIMUM 125.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE SECONDARY AC VOLTS MINIMUM 750.78 AND AC VOLTS MAXIMUM 797.22
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 1
BODY HEIGHTINCHES MINIMUM 2.560 AND INCHES MAXIMUM 2.750
MAXIMUM OPERATING TEMPCELSIUS 130.0
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED HOLE(S)
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.359 AND INCHES MAXIMUM 1.391
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.234 AND INCHES MAXIMUM 1.266
FREQUENCY RATINGSINGLE COMPONENT KILOHERTZ MINIMUM 5.0 AND KILOHERTZ MAXIMUM 6.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
BODY LENGTHINCHES MINIMUM 1.810 AND INCHES MAXIMUM 1.940
BODY WIDTHINCHES MINIMUM 1.680 AND INCHES MAXIMUM 1.810
TERMINAL TYPE AND QUANTITYTURRET 6

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
YP01YP01-NOV-08YP81YP
ZI01ZI01-NOV-20ZI81ZI
A918DA1C01-JUN-06ZCDGX01CD5DCD GXA196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
TX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IAW MIL-E-17555

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
03-NOV-1971
NIIN status code
0

Request a quote