Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
163-1005Item number
NIIN 00-163-1005
Request a quote
Unit price
$232.18
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
12-NOV-71
Precious metals indicator
U
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$232.181U0ZQ22RXX-$0.00A
01-OCT-2026DSJSMSEA0.0000$232.181U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
SM-B-52546980063
US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
A32ATX4D
SM-B-52546980223
UNITED TRANSFORMER CORP SUB OF OPT INDUSTRIES INC
A595TX4B
A1-1250695970
MTE CORP MILWAUKEE TRANSFORMER CO
A596CL3B
SM-B-52546915634
MAGNETIKA INC
A525TX

Characteristics

WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 390.0
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 33.50
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 15.50
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 23.30
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 12.50
SPECIAL FEATURES1 PRIMARY WINDING; 5 SECONDARY WINDINGS
THREAD SERIES DESIGNATORSINGLE GROUP UNF
TERMINAL TYPE AND QUANTITYSOLDER STUD 13
BODY HEIGHTINCHES MINIMUM 2.875 AND INCHES MAXIMUM 2.937
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 175.0
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 1.2
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC MAXIMUM 675.0
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 2.468 AND INCHES MAXIMUM 2.531
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.843 AND INCHES MAXIMUM 1.906
FREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 47.5 AND HERTZ MAXIMUM 440.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE
BODY LENGTHINCHES MAXIMUM 3.219
BODY WIDTHINCHES MAXIMUM 2.406
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 5
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.190
MOUNTING METHODSINGLE GROUP THREADED STUD(S)
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY QUANTITY4

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YB01YB01-FEB-94YB81YB
A918DA0001-JUN-06ZCDGX01CD5DCD GXBDA196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
RX
ARC
X

Freight

ACTY CD
CL
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
3.3000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0400
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
01-DEC-1974
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.