Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
163-2291Item number
NIIN 00-163-2291
Request a quote
Unit price
$4,685.92
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
03-NOV-71
Precious metals indicator
U
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$4,685.921U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$4,685.921U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
109-02420747
L-3 COMMUNICATIONS CORPORATION DBA GLOBAL NETWORK SOLUTIONS DIV AYDIN COMMUNICATIONS DIVISION
A32AKE3D
247ASC1356-00130003
NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
A721KE3D
109-02433214
AYDIN CORP AYDIN CONTROLS DIV
HC15ZZAC

Characteristics

WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 7
INCLOSURE TYPEHERMETICALLY SEALED WITH OIL
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED STUD(S)
BODY HEIGHTINCHES NOMINAL 3.433
BODY WIDTHINCHES NOMINAL 3.906
RELIABILITY INDICATORNOT ESTABLISHED
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT THREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 25
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 150.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 18.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 200.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 6.30
TRANSFORMER WINDING CONNECTION TYPEDELTA-WYE
WINDING SHIELDING METHODSINGLE COMPONENT CORE GROUNDED
BODY LENGTHINCHES NOMINAL 5.658
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC MAXIMUM 250.0
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 12.0
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 600.0
SPECIAL FEATURES7 SECONDARY WINDINGS
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 500.0
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 24.00
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.138

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
ZC01ZC01-APR-91ZC81ZC
ZI01ZI01-NOV-20ZI81ZI
FXGXDF3D01-JUN-06ZSXGX01SX5DGX TUFXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
KE
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
8.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.2700
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
30-JUN-1977
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.