Catalog item

TRANSFORMER,CURRENT

5950FSC
00NCB code
187-4366Item number
NIIN 00-187-4366
Request a quote
Unit price
$762.52
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00738
PINC
0000738
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$762.521U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$762.521U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
G17T6722-7095683
GENERAL STORES SUPPLY OFFICE
H39XXX3D
752X41G1703497
GENERAL ELECTRIC CO OUTDOOR BREAKER BUSINESS SECTION
HC16ZZAC
JNM-2-75X41G1703497
GENERAL ELECTRIC CO OUTDOOR BREAKER BUSINESS SECTION
HC16ZZAC
9JL9ABB103497
GENERAL ELECTRIC CO OUTDOOR BREAKER BUSINESS SECTION
H595TXB
9JL9ABB03497
GENERAL ELECTRIC CO OUTDOOR BREAKER BUSINESS SECTION
H595TXB
G17-T-6722-7003497
GENERAL ELECTRIC CO OUTDOOR BREAKER BUSINESS SECTION
H595TXB

Characteristics

INCLOSURE TYPEOPEN
RELIABILITY INDICATORNOT ESTABLISHED
NONDEFINITIVE SPEC/STD DATACLASS 3 AND GRADE NSS
WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE PRIMARY AMPERES AC MAXIMUM 500.0
WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE SECONDARY AMPERES AC MAXIMUM 5.0
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS MAXIMUM 500.00
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.375
MOUNTING METHODSINGLE GROUP FLANGE AND UNTHREADED HOLE(S)
MOUNTING HOLE DIAMETERSINGLE GROUP INCHES NOMINAL 0.562
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
INSTALLATION FOR WHICH DESIGNEDINDOOR NONPORTABLE
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-I-1361
TERMINAL TYPE AND QUANTITYBUS (BAR) CONDUCTOR 2 AND SLOTTED LUG 2
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.375
MOUNTING FACILITY QUANTITY4
FREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 55.0 AND HERTZ MAXIMUM 66.0
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 1

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZU01ZU01-JUL-05ZU81ZU
N9BNDN3H01-JUL-05ZHDGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
42
Container, watervaporproof bag, heat sealed, container
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
EA
MIL-DTL-17667, neutral wrapping paper
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.2000
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
13-JAN-1968
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.