Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
232-5156Item number
NIIN 00-232-5156
Request a quote
Unit price
$299.12
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
J
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$299.12
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
T5621340
ITT TELECOM PRODUCTS CORP NETWORK SYSTEMS DIV
H595TXB
M901432SUB7PT221921
RCA CORP DISTRIBUTOR AND SPECIAL PRODUCTS DIV
H59XXX1B
K949081-149671
LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN DIV LOCKHEED MARTIN
H59XXX3B
M901432SUB7PT249671
LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN DIV LOCKHEED MARTIN
H595ZZ3B
XT402449671
LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN DIV LOCKHEED MARTIN
H59XXX3B
K901432-50149671
LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN DIV LOCKHEED MARTIN
H59XXX3B
2E374013
BRABROOK A N INC
A32XXX3D
842080089
EMERSON ELECTRIC CO WHITE-RODGERS DIV
H59XXX3B
T5602036
GILLIE POWER EQUIPMENT COMPANY DBA POWER EQUIPMENT COMPANY
A59XXX3B

Characteristics

BODY LENGTHINCHES NOMINAL 4.281
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 6.45
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.125
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.000
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 60.0
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED STUD(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 3
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 4.5
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 2.0
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 690.00
BODY WIDTHINCHES NOMINAL 4.406
BODY HEIGHTINCHES NOMINAL 5.656
INCLOSURE TYPEHERMETICALLY SEALED
THREAD QUANTITY PER INCH20
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 110.00 AND AC VOLTS NOMINAL 125.00 AND AC VOLTS NOMINAL 150.00 AND AC VOLTS NOMINAL 210.00 AND AC VOLTS NOMINAL 240.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 5.00
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 13
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.250
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 100.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedPICAPICA LOAAuth collab
YB01YB01-NOV-98YB81YB
DGX1DS1C01-NOV-25GX01GX

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
60Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.4000
UP SZ MAXB
4.40000
UP SZ MAXL
5.70000
UP SZ MAXH
4.30000
Unit pack cube
0.0620
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
15-DEC-1974
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59505950-00-194-6808701-JUL-2026A
59505950-00-232-5161701-JUL-2026A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.