Catalog item

TRANSFORMER,POWER AUTOTRANSFORME

5950FSC
00NCB code
252-8091Item number
NIIN 00-252-8091
Request a quote
Unit price
$12,185.61
Unit of issue
EA
Source of supply
SMS
DEMIL code
B

Identification

Item name code
36166
PINC
0036166
Criticality code
X
II
0
DEMIL code
B
DEMIL integrity code
3
NIIN assigned
01-JAN-63
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8504500000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$12,185.611U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$12,185.611U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
DU74-16563B150
RAYTHEON COMPANY DBA RAYTHEON CO
A325CX
DU74-1656SUB33B150
RAYTHEON COMPANY DBA RAYTHEON CO
A525CX
DU74-1656SUB349956
RAYTHEON COMPANY DIV CORP
A595CX3B
DU74-165649956
RAYTHEON COMPANY DIV CORP
A595CX3B
DU74-1656SUB354X10
RAYTHEON COMPANY
A525ZZ
DU74-165654X10
RAYTHEON COMPANY
A525ZZ

Characteristics

NOMINAL THREAD SIZESINGLE GROUP INCHES 0.164
WINDING POWER RATINGSINGLE COMPONENT SINGLE PRIMARY OUTPUT KILOVOLT-AMPERES 15.0
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY INPUT AC VOLTS NOMINAL 135.00
BODY LENGTHINCHES NOMINAL 5.313
WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE PRIMARY OUTPUT AMPERES AC MAXIMUM 15.0
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY, FIXED AUTOTRANSFORMER TYPE 1
BODY WIDTHINCHES NOMINAL 4.503
BODY HEIGHTINCHES NOMINAL 6.625
INCLOSURE TYPEFULLY INCLOSED
THREAD QUANTITY PER INCH32
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 4.250
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.750
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 60.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED STUD(S)
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY OUTPUT AC VOLTS NOMINAL 72.00 AND AC VOLTS NOMINAL 95.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 119.00 AND AC VOLTS NOMINAL 123.00 AND AC VOLTS NOMINAL 127.00 AND AC VOLTS NOMINAL 131.00
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYSTANDOFF, SOLDER LUG 9

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-JAN-02YA81YA
YB01YB01-MAY-97YB81YB
ZH01ZH01-APR-91ZH81ZH
ZR01ZR01-JUL-97ZR81ZR
ZU01ZU01-JUL-05ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
N9BNDN3L01-NOV-05ZGHGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69FZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
22.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0960
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP056: MERCURY OR MERCURY

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
D4
Dt stdzn dec
14-OCT-1971
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.