Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
253-3553Item number
NIIN 00-253-3553
Request a quote
Unit price
$2,524.90
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
05-JAN-72
Precious metals indicator
A
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$2,524.901U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$2,524.901U0-------$0.00I

Part numbers

Part number
752389-1
CAGE
96214
RAYTHEON COMPANY DBA RAYTHEON
CAGE status
A
RNCC
3
RNVC
2
Document availability code
A
RNAAC
TX
RNFC
3
RNSC
D

Characteristics

WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES DC NOMINAL 1.5
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.312
OVERALL HEIGHTINCHES MAXIMUM 2.200
OVERALL WIDTHINCHES MAXIMUM 3.650
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 9.80
RELIABILITY INDICATORNOT ESTABLISHED
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONMOISTURE RESISTANT AND VIBRATION RESISTANT
OVERALL LENGTHINCHES MAXIMUM 4.800
INCLOSURE TYPEFULLY INCLOSED
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY AMPERES DC NOMINAL 2.2
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES DC NOMINAL 750.0
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES DC NOMINAL 600.0
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 4
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.164
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 38.80
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED HOLE(S)
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 19.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS MINIMUM 103.50 AND AC VOLTS MAXIMUM 126.50
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 19.00
SPECIAL FEATURESCURRENT IS RECTIFIED
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 16
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT THREE PHASE TO THREE PHASE
TRANSFORMER WINDING CONNECTION TYPETAYLOR
MAXIMUM OPERATING TEMPCELSIUS 130.0
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.000

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YB01YB01-APR-91YB81YB
ZH01ZH01-AUG-95ZH81ZH
ZT01ZT01-APR-91ZT81ZT
ZU01ZU01-APR-91ZU81ZU
N9BNDN3C01-NOV-05ZGHGX01GH5DGXKEN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
KE
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
5.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.1450
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
17-JAN-1972
NIIN status code
0

Request a quote