Catalog item
Request a quoteTRANSFORMER,POWER
5950FSC
00NCB code
421-9744Item number
NIIN 00-421-9744
- Unit price
- $1,186.16
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 32496
- PINC
- 0032496
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 21-DEC-70
- Precious metals indicator
- U
- Hazardous material indicator
- P
- FedMall
- Y
Management
- Effective date
- 01-OCT-2026
- Major organizational entity
- DS
- Acquisition advice code
- J
- Source of supply
- SMS
- Unit of issue
- EA
- Unit of measure quantity
- 0.0000
- Unit price
- $1,186.16
- Quantity per unit pack
- 1
- Controlled inventory item code
- U
- Shelf-life code
- 0
- Management control
- -------
- Net price
- $0.00
- USC
- I
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| L504000359 | 36090 LOCKHEED MARTIN LIBRASCOPE CORPORATION | A | 5 | 2 | 5 | HD | 3 | D |
| C16769 | 72149 ELECTRONIC TRANSFORMER CORP DIV ELECTRONIC TRANSFORMER CORPORATION | A | 5 | 2 | 5 | ZZ | ||
| BTC-14462 | 89870 BERKSHIRE TRANSFORMER | A | 5 | 9 | 5 | ZZ | B | |
| 1569243 | 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER | A | 3 | 2 | A | TX | 3 | D |
Characteristics
| MAXIMUM OPERATING TEMP | CELSIUS 70.0 |
|---|---|
| INCLOSURE TYPE | HERMETICALLY SEALED |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 8.25 AND AC VOLTS NOMINAL 12.00 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 8.25 AND AC VOLTS NOMINAL 12.00 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 108.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 122.00 |
| TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 10001-1569243 |
| THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TERMINAL TYPE AND QUANTITY | TURRET 10 |
| WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 2 |
| NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.138 |
| WINDING SHIELDING METHOD | SINGLE COMPONENT EXTERNAL INCLOSURE |
| OVERALL HEIGHT | INCHES MAXIMUM 3.545 |
| OVERALL LENGTH | INCHES MAXIMUM 2.312 |
| FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.677 AND INCHES MAXIMUM 1.697 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.427 AND INCHES MAXIMUM 1.447 |
| MOUNTING METHOD | SINGLE GROUP THREADED STUD(S) |
| OVERALL WIDTH | INCHES MAXIMUM 2.062 |
| MOUNTING FACILITY QUANTITY | 4 |
MOE rules
- MOE rule
- DGX1
- MOE CD
- DS
- AMC
- 1
- AMSC
- C
- Date assigned
- 01-NOV-25
- PICA
- GX
- PICA LOA
- 01
- Auth collab
- GX
Freight
- ACTY CD
- HD
- NMFC
- 063420
- NMFC sub
- Z
- Uniform freight class
- 35355
- Less than truckload
- W
- Water commodity code
- 595
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- TRANSFORMERS,NOI,OR TRANSFORMER PAR
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 60F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 10Physical protection
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- DOAny suitable fiber box included in this table may be used (see J.4.9.1).
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- UItems or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
- Unit pack weight
- 2.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0160
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
- Supplemental instructions
- IP025: PACKAGING, MARKING,
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 07-JAN-1971
- NIIN status code
- 0
Request a quote