Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
433-2444Item number
NIIN 00-433-2444
Request a quote
Unit price
$334.76
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
30-JUL-70
Precious metals indicator
A
Hazardous material indicator
P
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAXSMSEA0.0000$334.761U0ZQ2200X-$0.00A
01-OCT-2026DSXSMSEA0.0000$334.761U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
SMD201864980063
US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
A321CL3D
636205-196214
RAYTHEON COMPANY DBA RAYTHEON
A324CL3D

Characteristics

FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 6
INCLOSURE TYPEFULLY INCLOSED
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED HOLE(S)
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS MINIMUM 104.00 AND AC VOLTS MAXIMUM 118.00
TEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 80063-S--D-2018649
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.820 AND INCHES MAXIMUM 1.840
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.240 AND INCHES MAXIMUM 1.260
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES AC NOMINAL 1.0
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 28.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 6.30
BODY WIDTHINCHES MAXIMUM 2.120
BODY HEIGHTINCHES MAXIMUM 2.300
MAXIMUM OPERATING TEMPCELSIUS 105.0
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC NOMINAL 2.0
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 2
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
BODY LENGTHINCHES MAXIMUM 2.660
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.138

MOE rules

MOE rule
A918
MOE CD
DA
AMC
3
AMSC
D
Date assigned
01-JUN-06
IMC
Z
IMCA
CL
PICA
GX
PICA LOA
01
SICA
CD
SICA LOA
5D
Auth collab
CD GX
Supp collab
CL
Fmr MOE rl
A196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
CL
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69FZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
13-AUG-1970
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.