Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
461-5484Item number
NIIN 00-461-5484
Request a quote
Unit price
$1,397.03
Unit of issue
EA
Source of supply
SMS
DEMIL code
B

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
B
DEMIL integrity code
3
NIIN assigned
02-MAY-69
Precious metals indicator
U
Hazardous material indicator
P
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$1,397.031U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,397.031U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
V00040-00150097
RADIONICS TECHNOLOGIES INC
R595TXB
W-765508715
CEN ELECTRONICS A DIV OF CHLORIDE POWER ELECTRONICS INC
A595TX1B
V00040-00112436
BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC. DIV BAE SYSTEMS INFORMATION & ELECTRONIC SYSTEMS INTEGRATION INC
A321TX1D

Characteristics

INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 13
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC MAXIMUM 100.0
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 300.0
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 6.5
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 14.50
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE
BODY LENGTHINCHES MAXIMUM 3.218
BODY WIDTHINCHES NOMINAL 2.438
BODY HEIGHTINCHES MAXIMUM 2.718
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 105.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 125.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 15.00
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.625
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.875
MOUNTING SLOT WIDTHSINGLE GROUP INCHES NOMINAL 0.188
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 12.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 54.00
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 4
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 1.2
MOUNTING METHODSINGLE GROUP FLANGE AND SLOT
MOUNTING FACILITY QUANTITY4
INCLOSURE TYPEOPEN

MOE rules

MOE rule
N9BN
MOE CD
DN
AMC
3
AMSC
R
Date assigned
01-JUL-05
IMC
Z
IMCA
KE
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX
Supp collab
KE
Fmr MOE rl
N9ND

Service data

Navy

COG
9B

Freight

ACTY CD
KE
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
2.5000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
07-MAY-1969
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.