Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
464-2511Item number
NIIN 00-464-2511
Request a quote
Unit price
$1,295.98
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
12-MAY-69
Precious metals indicator
U
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$1,295.981U0NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$1,295.981U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,295.981U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
WE194326543
WEMS ELECTRONICS TRANSFORMER GROUP
A595TXB
W519100348
MICROTRAN CO INC
H595KE3B
5T80604620
RAYCO ELECTRONIC MANUFACTURING, INC. DIV RAYCO ELECTRONICS MFG INC
A325ZZ
1018784-00105037
ANACOMP, INC.
A591KE3B
101878400104620
RAYCO ELECTRONIC MANUFACTURING, INC. DIV RAYCO ELECTRONICS MFG INC
A525TX
727305614
ALTEC LANSING CORP SOUND PRODUCTS DIV
H595KE3B
701215634
MAGNETIKA INC
A595KEB
7882115634
MAGNETIKA INC
A525TX
882115634
MAGNETIKA INC
A595TXB
WE194315634
MAGNETIKA INC
A525TX

Characteristics

BODY HEIGHTINCHES NOMINAL 4.820
BODY WIDTHINCHES NOMINAL 2.540
INCLOSURE TYPEFULLY INCLOSED
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSECOND MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.685
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSECOND MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.850
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT THREE PHASE TO SINGLE PHASE
TRANSFORMER WINDING CONNECTION TYPEWYE-WYE
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL
BODY LENGTHINCHES NOMINAL 4.320
MOUNTING FACILITY QUANTITY2
TERMINAL TYPE AND QUANTITYSOLDER STUD 24
MOUNTING FACILITY QUANTITY6
MOUNTING METHODALL GROUPINGS THREADED HOLE(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 1
NOMINAL THREAD SIZEALL GROUPINGS INCHES 0.164
WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE SECONDARY AMPERES AC MAXIMUM 2.0
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00
THREAD SERIES DESIGNATORALL GROUPINGS UNIFIED NATIONAL COARSE (UNC)
DISTANCE BETWEEN MOUNTING FACILITY CENTERSFIRST MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.850
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE SECONDARY AC VOLTS MINIMUM 27.40 AND AC VOLTS MAXIMUM 197.00

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZH01ZH01-AUG-95ZH81ZH
ZJ01ZJ01-MAR-25ZJ81ZJ
FXGXDF1C01-JUN-06ZSXGX01SX5DGX TUFXTX
N9BNDN1C01-JUN-06ZKEGX01GH5DGXKE GTN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
KE
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
05Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
004
4 unit packs per intermediate container
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
GB
MIL-PRF-121, greaseproof, waterproof barrier
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
8.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0690
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
21-MAY-1969
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.