Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
500-4198Item number
NIIN 00-500-4198
Request a quote
Unit price
$339.56
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
M
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8504320000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAVSMSEA0.0000$339.561U0ZQ2200X-$0.00A
01-OCT-2026DFVSMSEA0.0000$339.561U0NSF9EH-N$0.00F
01-OCT-2026DNYSMSEA0.0000$339.561U09B-----$0.00N
01-OCT-2026DSYSMSEA0.0000$339.561U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
2S1F19804
SCHNEIDER ELECTRIC USA, INC. DBA SCHNEIDER ELECTRIC 324
H395ZZ
2KVATYPESU240-48-0PRI120-240SEC55947
SQUARE D CO SORGEL MFG PLANT
H595CX1B
2S1B55947
SQUARE D CO SORGEL MFG PLANT
HE8475D
2S1F55947
SQUARE D CO SORGEL MFG PLANT
H593CX4B
A238255947
SQUARE D CO SORGEL MFG PLANT
H595CX1B
4027X4072759
UNITED CATALYSTS INC
A595CX1B

Characteristics

WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 2 AND SECONDARY 2
WINDING OPERATING VOLTAGESINGLE COMPONENT ALL PRIMARY AC VOLTS NOMINAL 240.00
DISTANCE BETWEEN MOUNTING FACILITY CENTERSSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 6.000
TERMINAL TYPE AND QUANTITYWIRE LEAD 8
BODY HEIGHTINCHES NOMINAL 10.500
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
MAXIMUM TRANSFORMER POWER RATINGSINGLE COMPONENT KILOVOLT-AMPERE 2.0
BODY LENGTHINCHES NOMINAL 6.125
BODY WIDTHINCHES NOMINAL 6.375
MOUNTING SLOT WIDTHSINGLE GROUP INCHES NOMINAL 0.375
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 60.0
COOLING METHODSELF-COOLED
INCLOSURE TYPEFULLY INCLOSED
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP SLOT
COOLING TYPEFINS
WINDING OPERATING VOLTAGESINGLE COMPONENT ALL SECONDARY AC VOLTS NOMINAL 120.00

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZA01ZA01-APR-08ZA81ZA
ZC01ZC01-JAN-14ZC81ZC
ZN01ZN01-DEC-25ZN81ZN
A918DA3L01-JUN-06ZCDGX01CD5DCD GXA196
FXGXDF3L01-JUN-06ZSXGX01SX5DGX TUFXTX
G170T10001-APR-91C174817 75
N9BNDN3L01-JUN-06ZGHGX01GH5DGXGT HDN9ND
VJ01VJ01-NOV-19VJ81VJ

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
6
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Unit pack weight
51.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.5700
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
GX
Dt stdzn dec
01-SEP-2023
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59505950-00-976-2056522-JUL-2026A
59505950-01-030-0777522-JUL-2026A
59505950-00-877-2258522-JUL-2026A

Request a quote