Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
509-8431Item number
NIIN 00-509-8431
Request a quote
Unit price
$581.47
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAXSMSEA0.0000$581.471U0AQ2200X-$0.00A
01-OCT-2026DSXSMSEA0.0000$581.471U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
2000779272314
BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
A32ATX3D
819245018876
US ARMY AVIATION AND MISSILE COMMAND
A595TXB

Characteristics

FREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 400.0
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED STUD(S)
INCLOSURE TYPEFULLY INCLOSED
TERMINAL TYPE AND QUANTITYWIRE LEAD 23
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 2.0
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL
BODY LENGTHINCHES NOMINAL 5.875
BODY WIDTHINCHES NOMINAL 4.750
BODY HEIGHTINCHES NOMINAL 3.938
WINDING OPERATING VOLTAGESINGLE COMPONENT ALL PRIMARY AC VOLTS NOMINAL 115.00
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 6.30
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 8.75
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 1.25
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 1.25
SPECIAL FEATURES2 PRIMARY WINDINGS; 8 SECONDARY WINDINGS; WINDINGS 5 AND 7 ARE CENTER TAPPED AND THE TAPS ARE CORE PROUNDED AND BROUGHT OUT TO TERMINALS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.750
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.625
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC MAXIMUM 4.0
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 200.0
RELIABILITY INDICATORNOT ESTABLISHED
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.164
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 600.0
FEATURES PROVIDEDCOLOR CODED LEAD
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 2 AND SECONDARY 8

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-NOV-08YA81YA
ZH01ZH01-APR-91ZH81ZH
ZW01ZW01-NOV-05ZW81ZW
A918DA3C01-JUL-05ZCDGX01CD5DCD GXCLA196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
16.5000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.2890
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
17-JUL-1967
NIIN status code
0

Cancelled and replaced NIINs

FSC
5950
Cancelled NIIN
5950-00-331-3162
NIIN status code
7
Effective date
02-JUL-2026
DEMIL code
A

Request a quote