Catalog item
Request a quoteTRANSFORMER,POWER
5950FSC
00NCB code
548-0491Item number
NIIN 00-548-0491
- Unit price
- $3,850.75
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 32496
- PINC
- 0032496
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-JAN-63
- Precious metals indicator
- A
- Hazardous material indicator
- P
- Schedule B export code
- 8504320000
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | Z | SMS | EA | 0.0000 | $3,850.75 | 1 | U | 0 | 9B----- | $0.00 | N |
| 01-OCT-2026 | DS | Z | SMS | EA | 0.0000 | $3,850.75 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|---|
| 5326GP3 | 75138 SHERJOR INC | H | 5 | 9 | 1 | HD | 1 | B | |
| 5326 | 75138 SHERJOR INC | H | 5 | 9 | X | XX | 3 | B | |
| S6202-3226697 | 80064 NAVAL SHIP SYSTEMS COMMAND | A | 3 | 2 | X | XX | 3 | D | |
| 56202F3226697 | 80064 NAVAL SHIP SYSTEMS COMMAND | A | 5 | 2 | 6 | 9Z | 4 | D | |
| S6202F3226697GP3 | 80064 NAVAL SHIP SYSTEMS COMMAND | A | 5 | 2 | A | CX | 1 | D | |
| TF-5018/SPS-503 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 5 | 2 | 6 | 9Z | 4 | D | |
| MIL-T-15108C | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 4 | 1 | E | TX | |||
| 240-001-896 | 04801 L3HARRIS MARITIME POWER & ENERGY SOLUTIONS, INC | A | 5 | 9 | 5 | ZZ | B | ||
| 101209-1 | 0UU57 BLUE WAVE ULTRASONICS INC | A | C | 1 | 6 | ZZ | AC |
Characteristics
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 450.00 |
|---|---|
| INCLOSURE TYPE | FULLY INCLOSED |
| MOUNTING FACILITY QUANTITY | 4 |
| MAXIMUM TRANSFORMER POWER RATING | SINGLE COMPONENT KILOVOLT-AMPERE 5.0 |
| WINDING SHIELDING METHOD | SINGLE COMPONENT EXTERNAL INCLOSURE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 8.000 |
| OVERALL WIDTH | INCHES NOMINAL 10.594 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 120.00 |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 4 |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| OVERALL LENGTH | INCHES NOMINAL 12.656 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 8.000 |
| MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.438 |
| FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 60.0 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 8.000 |
| OVERALL HEIGHT | INCHES NOMINAL 10.219 |
| MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| COOLING TYPE | FINS |
| COOLING METHOD | SELF-COOLED |
| WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE PRIMARY AMPERES AC NOMINAL 11.1 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY AMPERES AC NOMINAL 41.7 |
| WINDING POWER RATING | SINGLE COMPONENT SINGLE PRIMARY KILOVOLT-AMPERES 5.0 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YA01 | YA | 01-JAN-02 | YA | 81 | YA | ||||||||
| YD01 | YD | 01-SEP-16 | YD | 81 | YD | ||||||||
| ZC01 | ZC | 01-NOV-97 | ZC | 81 | ZC | ||||||||
| ZU01 | ZU | 01-JUL-05 | ZU | 81 | ZU | ||||||||
| ZW01 | ZW | 01-NOV-98 | ZW | 81 | ZW | ||||||||
| N9BN | DN | 1 | T | 01-JUN-06 | Z | HD | GX | 01 | GH | 5D | GX | HX GT HD | N9ND |
Service data
Navy
- COG
- 9B
Freight
- ACTY CD
- XX
- NMFC
- 063420
- NMFC sub
- Z
- Uniform freight class
- 35355
- Less than truckload
- W
- Water commodity code
- 595
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- TRANSFORMERS,NOI,OR TRANSFORMER PAR
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 60Z0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- 000No intermediate container quantity specified (000)
- Method of preservation
- 41Watervaporproof bag, heat sealed
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- ADCushion, anchor, block or brace as required.
- THK
- M3 inches thick
- Unit cont
- F2ASTM D6251, Type III, Class 2, overseas cleated plywood box or ASTM-D6880, Class 2, heavy duty nailed wood box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 06Delicate instrument and Arrow up
- Inter cont
- 00No requirement.
- Lvl A
- FPacking is not required: the unit container shall also serve as the shipping container.
- Lvl b
- FPacking is not required: the unit container shall also serve as the shipping container.
- Unit pack weight
- 80.0000
- UP SZ MAXB
- 15.00000
- UP SZ MAXL
- 15.00000
- UP SZ MAXH
- 20.00000
- Unit pack cube
- 2.6040
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 2
- Orig stdzn dec
- CX
- Dt stdzn dec
- 05-AUG-1982
- NIIN status code
- 0
Cancelled and replaced NIINs
- FSC
- 5950
- Cancelled NIIN
- 5950-01-342-2146
- NIIN status code
- 5
- Effective date
- 22-JUL-2026
- DEMIL code
- A
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.