Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
557-6646Item number
NIIN 00-557-6646
Request a quote
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
M
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P
Last known source of supply
S9E

Part numbers

Part number
N285306-1
CAGE
06845
RAYTHEON COMPANY DBA RAYTHEON CO
CAGE status
A
RNCC
3
RNVC
2
Document availability code
1
RNAAC
TX
RNFC
3
RNSC
D

Characteristics

MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP FLANGE AND UNTHREADED HOLE(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 3
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.620
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 2.25
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 119.00
INCLOSURE TYPEHERMETICALLY SEALED
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 150.0
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 23.00
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 750.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT THREE PHASE TO THREE PHASE
BODY LENGTHINCHES NOMINAL 4.250
BODY WIDTHINCHES NOMINAL 2.250
BODY HEIGHTINCHES NOMINAL 3.630
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
SPECIAL FEATURESWINDING SHIELDING METHOD INTERNALLY SHIELDED GROUNDED BANDING
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 12
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 26.00
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.250

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedAcquisition advice codePICAPICA LOAAuth collab
G940T10001-OCT-93B944875 94
VJ01VJ01-FEB-19VJ81VJ

Freight

ACTY CD
XX

Packaging

Unit and preservation

PICA SICA
P
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
FA
MIL-P-130, laminated and creped wrapping paper
Cush dun
BG
A-A-1898, Grade II, water resistant cellulosic cushioning
THK
B
1/2 inch thick
Unit cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
PKG data source
A

Unit pack

PICA SICA
P
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
21-MAR-1968
NIIN status code
0

Request a quote