Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
617-4963Item number
NIIN 00-617-4963
Request a quote
Unit price
$63.97
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$63.971U0ZQ2300X-$0.00A
01-OCT-2026DMJSMSEA0.0000$63.971U0Z15B2---$0.00M
01-OCT-2026DNJSMSEA0.0000$63.971U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$63.971U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
494250-23830086
L3HARRIS MARITIME POWER & ENERGY SOLUTIONS, INC. DBA SPD ELECTRICAL SYSTEMS, INC.
A515TX3D
24926336378
RAYTHEON TECHNICAL SERVICES COMPANY
R596TX3B
PMS70A80089
EMERSON ELECTRIC CO WHITE-RODGERS DIV
H595TX3B
TF4RX03JB00281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A51ETX3D
MIL-T-2781349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETXB
MIL-PRF-2781349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
MS90027-296906
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22ETX3D

Characteristics

WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE PRIMARY MILLIAMPERES AC MAXIMUM 690.0
INCLOSURE TYPEHERMETICALLY SEALED
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 2.0
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.125
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 6.30
MOUNTING METHODSINGLE GROUP THREADED STUD(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 3
BODY LENGTHINCHES NOMINAL 3.562
BODY WIDTHINCHES NOMINAL 3.062
RELIABILITY INDICATORNOT ESTABLISHED
MOUNTING FACILITY QUANTITY4
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 5.00 AND AC VOLTS NOMINAL 6.30
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 105.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 125.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 650.00
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-T-27
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.625
BODY HEIGHTINCHES NOMINAL 3.875
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.164
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 4.0
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 60.0
MAXIMUM OPERATING TEMPCELSIUS 105.0
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE
SPECIFICATION/STANDARD DATAGOVERNMENT STANDARD 96906--S90027
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 12
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES DC MAXIMUM 70.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-JAN-02YA81YA
YB01YB01-APR-91YB81YB
YD01YD01-FEB-17YD81YD
YY01YY01-FEB-15YY81YY
ZF01ZF01-APR-91ZF81ZF
ZH01ZH01-APR-91ZH81ZH
ZR01ZR01-APR-91ZR81ZR
ZW01ZW01-NOV-98ZW81ZW
A918DA1T01-JUN-06ZCDGX01CD5DCD GXA196
MC49DM1T01-JUN-06ZPAGX01PA5DGX PAMC13
N9BNDN1T01-JUN-06ZGHGX01GH5DGXGT KE HX HDN9ND
VJ01VJ01-FEB-19VJ81VJ

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
3
Matcat 4 5
00
ARC
X

Navy

COG
9B

Marine Corps

SAC
1
CEC
5
MEC
B2

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
6.8000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0870
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
15-DEC-1974
NIIN status code
0

Cancelled and replaced NIINs

FSC
5950
Cancelled NIIN
5950-00-556-0524
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.