Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
647-5069Item number
NIIN 00-647-5069
Request a quote
Unit price
$159.04
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$159.041U0ZQ2200X-$0.00A
01-OCT-2026DNJSMSEA0.0000$159.041U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$159.041U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
D16058880
MEGGITT (NEW HAMPSHIRE), INC
A595TX1B
C1386-4458880
MEGGITT (NEW HAMPSHIRE), INC
A395TX1D
A1386-4495711
CYCLE TRANSFORMER CORP
H59XXX3B

Characteristics

FREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 400.0
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.094
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 215.00
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 2
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 1.5
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE AND BROUGHT OUT TO TERMINAL
MOUNTING FACILITY QUANTITY4
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
MOUNTING METHODSINGLE GROUP FLANGE AND UNTHREADED HOLE(S)
TERMINAL TYPE AND QUANTITYSOLDER STUD 8
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.094
BODY LENGTHINCHES NOMINAL 3.250
BODY OUTSIDE DIAMETERINCHES NOMINAL 2.562
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 88.00 AND AC VOLTS NOMINAL 115.00
INCLOSURE TYPEHERMETICALLY SEALED
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 6.30
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 30.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-JAN-02YA81YA
ZW01ZW01-NOV-98ZW81ZW
A918DA0001-JUN-06ZCDGX01CD5DCD GXA196
N9BNDN0001-JUN-06ZGHGX01GH5DGXHDNIND
VJ01VJ01-MAR-19VJ81VJ

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
26.7000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.4280
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
15-DEC-1974
NIIN status code
0

Cancelled and replaced NIINs

FSC
5950
Cancelled NIIN
5950-00-510-4626
NIIN status code
7
Effective date
01-JUL-2026
DEMIL code
A

Request a quote