Catalog item
Request a quoteTRANSFORMER,POWER
5950FSC
00NCB code
655-0748Item number
NIIN 00-655-0748
- Unit price
- $94.11
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 32496
- PINC
- 0032496
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-JAN-63
- Precious metals indicator
- U
- Hazardous material indicator
- P
Management
- Effective date
- 01-OCT-2026
- Major organizational entity
- DS
- Acquisition advice code
- Y
- Source of supply
- SMS
- Unit of issue
- EA
- Unit of measure quantity
- 0.0000
- Unit price
- $94.11
- Quantity per unit pack
- 1
- Controlled inventory item code
- U
- Shelf-life code
- 0
- Management control
- -------
- Net price
- $0.00
- USC
- I
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| 2924674G1 | 49956 RAYTHEON COMPANY DIV CORP | A | 3 | 2 | X | XX | 3 | D |
| 292-4674G1 | 49956 RAYTHEON COMPANY DIV CORP | A | 5 | 2 | X | XX | 3 | D |
| AJ184 | 80223 UNITED TRANSFORMER CORP SUB OF OPT INDUSTRIES INC | A | 5 | 9 | 5 | 48 | B | |
| AJ184 | 15634 MAGNETIKA INC | A | 5 | 2 | 5 | 48 | ||
| 9072794 | 18876 US ARMY AVIATION AND MISSILE COMMAND | A | 5 | 2 | X | XX | 3 | D |
Characteristics
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.062 |
|---|---|
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 420.0 |
| NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.138 |
| WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE |
| BODY HEIGHT | INCHES NOMINAL 4.125 |
| WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| MOUNTING FACILITY QUANTITY | 4 |
| MOUNTING METHOD | SINGLE GROUP THREADED STUD(S) |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.250 |
| BODY LENGTH | INCHES NOMINAL 3.250 |
| BODY WIDTH | INCHES NOMINAL 2.812 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 109.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 121.00 AND AC VOLTS NOMINAL 127.00 |
| TERMINAL TYPE AND QUANTITY | STANDOFF, SOLDER LUG 8 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES AC MAXIMUM 35.0 |
| THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC KILOVOLTS NOMINAL 1.32 |
| THREAD QUANTITY PER INCH | 32 |
| INCLOSURE TYPE | HERMETICALLY SEALED |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|
| YB01 | YB | 01-SEP-08 | YB | 81 | YB | |||||
| ZH01 | ZH | 01-APR-91 | ZH | 81 | ZH | |||||
| ZJ01 | ZJ | 01-APR-25 | ZJ | 81 | ZJ | |||||
| ZU01 | ZU | 01-AUG-95 | ZU | 81 | ZU | |||||
| BGX1 | GE | 1 | L | 01-NOV-05 | GX | 01 | 48 | 5D | GX 48 | BTX1 |
Freight
- ACTY CD
- XX
- NMFC
- 063420
- NMFC sub
- Z
- Uniform freight class
- 35355
- Less than truckload
- W
- Water commodity code
- 595
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- TRANSFORMERS,NOI,OR TRANSFORMER PAR
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 10Physical protection
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- NAPPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
- THK
- C3/4 inch thick
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- DOAny suitable fiber box included in this table may be used (see J.4.9.1).
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- UItems or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
- Unit pack weight
- 5.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0560
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 17-JUL-1967
- NIIN status code
- 0
Cancelled and replaced NIINs
- FSC
- 5950
- Cancelled NIIN
- 5950-00-086-6467
- NIIN status code
- 7
- Effective date
- 01-JUL-2026
- DEMIL code
- A
Request a quote