Catalog item

COIL,ELECTRICAL

5950FSC
00NCB code
677-0567Item number
NIIN 00-677-0567
Request a quote
Unit price
$108.35
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32494
PINC
0032494
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8504500000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$108.351U0ZQ2200X-$0.00A
01-OCT-2026DFZSMSEA0.0000$108.351U0NSF9EH-N$0.00F
01-OCT-2026DNZSMSEA0.0000$108.351U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$108.351U0N-------$0.00I
01-OCT-2026GPJSMSEA0.0000$108.351U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
C0L59660532
TRANE U.S. INC. DBA THE TRANE CO
A595TX3B
C0L55160532
TRANE U.S. INC. DBA THE TRANE CO
A595TX3B
7505181978
PARKER-HANNIFIN CORPORATION DBA PNEUTRONICS DIV FLUID CONTROL DIVISION
A325ZZ
A3MP23-593781
PARKER-HANNIFIN CORP DIV FLUID CONTROL DIVISION
A595TX3B
3MP-2393781
PARKER-HANNIFIN CORP DIV FLUID CONTROL DIVISION
AC16ZZAC
7505193781
PARKER-HANNIFIN CORP DIV FLUID CONTROL DIVISION
A395TX
3MP23-5DTD5-6-6593781
PARKER-HANNIFIN CORP DIV FLUID CONTROL DIVISION
AC16ZZAC
TIP0001497403
CECOM LR CENTER
A523CT3D
5950006770567SCY13
E.C.A ETABLISSEMENT CENTRALD'APPROVISIONNEMENT DES FORCES ARMEE
R599YP4B

Characteristics

INCLOSURE TYPEOPEN
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE WINDING AC VOLTS NOMINAL 120.00
TERMINAL TYPE AND QUANTITYWIRE LEAD 2
MOUNTING METHODSINGLE GROUP UNTHREADED HOLE(S)
BODY OUTSIDE DIAMETERINCHES NOMINAL 2.375
WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE WINDING MILLIAMPERES DC MAXIMUM 510.0
RELIABILITY INDICATORNOT ESTABLISHED
WINDING QUANTITY1
MOUNTING FACILITY QUANTITY1
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 50.0 OR HERTZ NOMINAL 60.0
BODY LENGTHINCHES NOMINAL 2.125
MOUNTING HOLE DIAMETERSINGLE GROUP INCHES NOMINAL 0.750
RATING METHODSINGLE COMPONENT SINGLE WINDING ELECTRICAL

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WB01WB01-FEB-05WB81WB
YB01YB01-APR-91YB81YB
YD01YD01-SEP-16YD81YD
YJ01YJ01-APR-91YJ81YJ
YP01YP01-SEP-10YP81YP
ZC01ZC01-APR-91ZC81ZC
ZH01ZH01-APR-91ZH81ZH
ZK01ZK01-JUL-00ZK81ZK
ZU01ZU01-APR-91ZU81ZU
A918DA3C01-JUL-05ZCDGX01CD5DCD GXCLA196
C911GP3C01-JUL-05GX01XG5DXG GXC007
FXGXDF3C01-JUL-05ZSXGX01SX5DGX TUFXTX
N9BNDN3C01-JUL-05ZHDGX01GH5DGXHD GTN9ND
VJ01VJ01-FEB-19VJ81VJ

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
60F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
1.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0200
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
80242

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
21-MAR-1968
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
41304130-00-102-6682701-JUL-2026A
59505950-00-430-8246702-JUL-2026A
59505950-00-964-2264702-JUL-2026A
59505950-00-792-8240702-JUL-2026A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.