Catalog item

TRANSFORMER,POWER AUTOTRANSFORME

5950FSC
00NCB code
681-6862Item number
NIIN 00-681-6862
Request a quote
Unit price
$4,151.64
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
36166
PINC
0036166
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
01-JAN-63
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8504500000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$4,151.641U0PSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$4,151.641U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$4,151.641U0F-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
3150-511024655
GENRAD INC
H595CX4B
W5024655
GENRAD INC
H593CX4B
501083008
STACO ENERGY PRODUCTS CO DBA STACO ENERGY PRODUCTS CO
A32ETX
T501U83008
STACO ENERGY PRODUCTS CO DBA STACO ENERGY PRODUCTS CO
A595CX3B
W5013850
TECHNIPOWER LLC DBA UNIPOWER
A52ETX4D
3150-511013850
TECHNIPOWER LLC DBA UNIPOWER
A525CX4D

Characteristics

OVERALL WIDTHINCHES NOMINAL 6.125
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
ADJUSTMENT DEVICE DRIVE TYPESINGLE COMPONENT SHAFT
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 4.750
WINDING POWER RATINGSINGLE COMPONENT SINGLE PRIMARY OUTPUT KILOVOLT-AMPERES 2.1
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 50.0 AND HERTZ NOMINAL 60.0
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP UNTHREADED HOLE(S)
OVERALL LENGTHINCHES NOMINAL 6.812
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 4.750
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY OUTPUT AC VOLTS MINIMUM 0.00 AND AC VOLTS MAXIMUM 140.00
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 5
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY INPUT AC VOLTS NOMINAL 120.00
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY, VARIABLE AUTOTRANSFORMER TYPE 1
WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE PRIMARY OUTPUT AMPERES AC MAXIMUM 15.0
ADJUSTMENT METHOD AND QUANTITYSINGLE COMPONENT ADJUSTABLE CONTROL 1
INCLOSURE TYPEOPEN
MOUNTING HOLE DIAMETERSINGLE GROUP INCHES NOMINAL 0.312

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZT01ZT01-APR-91ZT81ZT
FXGXDF3R01-JUN-06ZSXGX01SX5DGX TUFXTX
N9BNDN3R01-JUN-06ZGHGX01GH5DGXHD GT KEN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
P

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69FZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
57.5000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
1.6500
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
D4
Dt stdzn dec
14-OCT-1971
NIIN status code
0