Catalog item

TRANSFORMER,POWER AUTOTRANSFORME

5950FSC
00NCB code
681-6930Item number
NIIN 00-681-6930
Request a quote
Unit price
$911.97
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
36166
PINC
0036166
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8504500000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$911.971U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$911.971U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$911.971U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
W5G324655
GENRAD INC
H593CX1B
9T92A603512
GENERAL ELECTRIC CO SPECIALTY TRANSFORMER DEPT
H39ETX4D
W5G313850
TECHNIPOWER LLC DBA UNIPOWER
A526TX4D

Characteristics

INCLOSURE TYPEPARTIALLY INCLOSED
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 50.0 OR HERTZ NOMINAL 60.0
RELIABILITY INDICATORNOT ESTABLISHED
MOUNTING HOLE DIAMETERSINGLE GROUP INCHES NOMINAL 0.312
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP UNTHREADED HOLE(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY, VARIABLE AUTOTRANSFORMER TYPE 1
BODY LENGTHINCHES MAXIMUM 5.625
BODY WIDTHINCHES MAXIMUM 4.500
BODY HEIGHTINCHES MAXIMUM 4.938
MAXIMUM OPERATING TEMPCELSIUS 105.0
TERMINAL TYPE AND QUANTITYTERMINAL BLOCK W/SCREWS 1
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.750
WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE PRIMARY OUTPUT AMPERES AC NOMINAL 5.8
WINDING POWER RATINGSINGLE COMPONENT SINGLE PRIMARY OUTPUT KILOVOLT-AMPERES 1.6
ADJUSTMENT METHOD AND QUANTITYSINGLE COMPONENT ADJUSTABLE CONTROL 1
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY INPUT AC VOLTS NOMINAL 240.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY OUTPUT AC VOLTS MINIMUM 0.00 AND AC VOLTS MAXIMUM 280.00
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT TWO PHASE TO TWO PHASE
ADJUSTMENT DEVICE DRIVE TYPESINGLE COMPONENT SHAFT
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.750

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
YA01YA01-SEP-00YA81YA
YD01YD01-SEP-16YD81YD
ZF01ZF01-MAY-11ZF81ZF
A918DA1H01-JUL-05ZCDGX01CD5DCD GXA196
FXGXDF1H01-JUL-05ZSXGX01SX5DGX TUFXTX

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69FZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
11.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.1840
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
D4
Dt stdzn dec
14-OCT-1971
NIIN status code
0

Cancelled and replaced NIINs

FSC
6120
Cancelled NIIN
6120-00-071-8016
NIIN status code
7
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.