Catalog item

TRANSFORMER,POWER AUTOTRANSFORME

5950FSC
00NCB code
754-9544Item number
NIIN 00-754-9544
Request a quote
Unit price
$1,042.93
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
36166
PINC
0036166
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-60
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8504500000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$1,042.931U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$1,042.931U0NSF9EH-V$0.00F
01-OCT-2026DNJSMSEA0.0000$1,042.931U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$1,042.931U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
1HM803UK58474
SUPERIOR ELECTRIC HOLDING GROUP LLC DIV SPECIALTY PRODUCT TECHNOLOGIES
AC15ZZAC
1HMQ03UK58474
SUPERIOR ELECTRIC HOLDING GROUP LLC DIV SPECIALTY PRODUCT TECHNOLOGIES
A52ATX3D
EP69-1858474
SUPERIOR ELECTRIC HOLDING GROUP LLC DIV SPECIALTY PRODUCT TECHNOLOGIES
A51ATX3D
11-888-00-00178022
NORTHROP GRUMMAN SYSTEMS CORPORATION
A595TX1D
5950PL09480679009H
JEDNOLITY INDEKS MATERIALOWY - UNIFORM MATERIAL INDEX
A699WP4B
7707382P803538
LOCKHEED MARTIN CORPORATION DIV RMS
A32ATX1D
5039-48905869
RAYTHEON COMPANY DIV RMD STRATEGIC
A526TX1D

Characteristics

CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 3.359 AND INCHES MAXIMUM 3.391
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 3.359 AND INCHES MAXIMUM 3.391
OVERALL WIDTHINCHES NOMINAL 4.250
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY INPUT AC VOLTS NOMINAL 120.00
WINDING POWER RATINGSINGLE COMPONENT SINGLE PRIMARY OUTPUT KILOVOLT-AMPERES 0.42
OVERALL LENGTHINCHES MINIMUM 4.710 AND INCHES MAXIMUM 4.790
FREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 400.0 AND HERTZ MAXIMUM 800.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
MOUNTING METHODSINGLE GROUP THREADED HOLE(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY, VARIABLE AUTOTRANSFORMER TYPE 1
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.190
BODY HEIGHTINCHES NOMINAL 4.125
INCLOSURE TYPEOPEN
MOUNTING FACILITY QUANTITY4
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY OUTPUT AC VOLTS MINIMUM 0.00 AND AC VOLTS MAXIMUM 140.00
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 4
RELIABILITY INDICATORNOT ESTABLISHED
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND VIBRATION RESISTANT AND HUMIDITY RESISTANT
WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE PRIMARY OUTPUT AMPERES AC MAXIMUM 3.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-JAN-06WP81WP
YB01YB01-APR-91YB81YB
ZG01ZG01-APR-91ZG81ZG
ZU01ZU01-JUL-05ZU81ZU
ZW01ZW01-DEC-05ZW81ZW
A918DA1R01-JUN-06ZCDGX01CD5DCD GXA196
FXGXDF1R01-JUN-06ZSXGX01SX5DGX TUFXTX
N9BNDN1R01-JUN-06ZGHGX01GH5DGXGT KE HDN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
60Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
016
16 unit packs per intermediate container
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
GB
MIL-PRF-121, greaseproof, waterproof barrier
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
2.0000
UP SZ MAXB
4.30000
UP SZ MAXL
4.80000
UP SZ MAXH
4.10000
Unit pack cube
0.0480
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
9T
Dt stdzn dec
03-JUL-1976
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59505950-00-436-3945701-JUL-2026A
59505950-00-820-0153702-JUL-2026A

Request a quote