Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
816-0263Item number
NIIN 00-816-0263
Request a quote
Unit price
$1,443.96
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-62
Precious metals indicator
A
Hazardous material indicator
P
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$1,443.961U0ZQ2200X-$0.00A
01-OCT-2026DSJSMSEA0.0000$1,443.961U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
952-0210-40027777
L3 TECHNOLOGIES, INC. DBA INSIGHT TECHNOLOGY DIVISION DIV INSIGHT TECHNOLOGY DIVISION
H596TX
TS257150508
MAGNETIC COMPONENTS INC
A515TX3D
P1-1452853854
MAGNESPEC INC
AC15ZZ9X
P1-1452353854
MAGNESPEC INC
AC15ZZ9X
257814856232
LOCKHEED MARTIN CORPORATION DIV RMS - MITCHEL FIELD
A525TX3D
P1-1452395970
MTE CORP MILWAUKEE TRANSFORMER CO
A59ATXB
P1-1452895970
MTE CORP MILWAUKEE TRANSFORMER CO
A595TXB
257814807187
HONEYWELL INTERNATIONAL INC. DBA HONEYWELL INTERNATIONAL
A32ATX3D
D90509798
PAYNE MAGNETICS, INC.
A595TXB
PEI256313483
PRECISION ELECTRONICS, INC
A526TX

Characteristics

TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 21
BODY LENGTHINCHES MINIMUM 1.484 AND INCHES MAXIMUM 1.516
BODY WIDTHINCHES MAXIMUM 1.125
MAXIMUM OPERATING TEMPCELSIUS 105.0
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY QUANTITY2
MOUNTING METHODSINGLE GROUP THREADED HOLE(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 7
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 6.00
SPECIAL FEATURESONE PRIMARY WINDING; SEVEN SECONDARY WINDINGS,WITH THIRD,FOURTH,AND SEVENTH SECONDARY CENTER TAPPED
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.109 AND INCHES MAXIMUM 1.141
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 0.797 AND INCHES MAXIMUM 0.829
OVERALL HEIGHTINCHES MAXIMUM 1.313
FREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 380.0 AND HERTZ MAXIMUM 420.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 6.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 6.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 26.00 AND AC VOLTS NOMINAL 52.00 AND AC VOLTS NOMINAL 115.00
WINDING POWER RATINGSINGLE COMPONENT THIRD SECONDARY VOLTS-AMPERES 0.009
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 6.00
WINDING POWER RATINGSINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 0.009
WINDING POWER RATINGSINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 0.009
WINDING POWER RATINGSINGLE COMPONENT FOURTH SECONDARY VOLTS-AMPERES 0.006
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC NOMINAL 1.5
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.112
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC NOMINAL 1.5
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC NOMINAL 1.0
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC NOMINAL 1.5

MOE rules

MOE rule
A918
MOE CD
DA
AMC
1
AMSC
C
Date assigned
01-JUN-06
IMC
Z
IMCA
CD
PICA
GX
PICA LOA
01
SICA
CD
SICA LOA
5D
Auth collab
CD GX
Supp collab
CL
Fmr MOE rl
A196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
60Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
JC
ASTM D4727/D4727M, domestic fiberboard used as pads, cells, die cuts or sleeves
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.2000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0100
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
17-JUL-1967
NIIN status code
0

Request a quote