Catalog item
Request a quoteTRANSFORMER,POWER
5950FSC
00NCB code
882-7271Item number
NIIN 00-882-7271
- Unit price
- $981.92
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 32496
- PINC
- 0032496
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-JAN-62
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- P
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $981.92 | 1 | U | 0 | 9B----- | $0.00 | N |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $981.92 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
- Part number
- B605-18
- CAGE
- 34228L3 TECHNOLOGIES, INC. DIV L3 KEO
- CAGE status
- A
- RNCC
- 3
- RNVC
- 2
- Document availability code
- 6
- RNAAC
- XX
- RNFC
- 3
- RNSC
- D
Characteristics
| RELIABILITY INDICATOR | NOT ESTABLISHED |
|---|---|
| WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.437 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.000 |
| TERMINAL TYPE AND QUANTITY | TURRET 12 |
| MOUNTING METHOD | SINGLE GROUP THREADED STUD(S) |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES AC MINIMUM 500.0 AND AMPERES AC MINIMUM 4.0 AND AMPERES AC MINIMUM 3.5 AND AMPERES AC MINIMUM 2.7 AND AMPERES AC MINIMUM 1.4 AND AMPERES AC MINIMUM 1.0 AND MILLIAMPERES AC MINIMUM 80.0 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 105.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 125.00 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 24.00 AND AC VOLTS NOMINAL 50.00 AND AC VOLTS NOMINAL 65.00 AND AC VOLTS NOMINAL 75.00 AND AC VOLTS NOMINAL 175.00 AND AC VOLTS NOMINAL 200.00 AND AC VOLTS NOMINAL 250.00 |
| THREAD SERIES DESIGNATOR | SINGLE GROUP UNF |
| THREAD QUANTITY PER INCH | 32 |
| NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.190 |
| MOUNTING FACILITY QUANTITY | 4 |
| BODY HEIGHT | INCHES NOMINAL 5.250 |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| BODY WIDTH | INCHES NOMINAL 3.375 |
| BODY LENGTH | INCHES NOMINAL 3.937 |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 60.0 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YA01 | YA | 01-JAN-02 | YA | 81 | YA | ||||||||
| ZW01 | ZW | 01-NOV-98 | ZW | 81 | ZW | ||||||||
| N9BN | DN | 3 | H | 01-JUN-06 | Z | HD | GX | 01 | GH | 5D | GX | HD | N9ND |
Service data
Navy
- COG
- 9B
Freight
- ACTY CD
- XX
- NMFC
- 063420
- NMFC sub
- Z
- Uniform freight class
- 35355
- Less than truckload
- W
- Water commodity code
- 595
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- TRANSFORMERS,NOI,OR TRANSFORMER PAR
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69FZ
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- UItems or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
- Unit pack weight
- 10.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.1210
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
- Supplemental instructions
- IP025: PACKAGING, MARKING,
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 17-JUL-1967
- NIIN status code
- 0
Request a quote