Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
932-6794Item number
NIIN 00-932-6794
Request a quote
Unit price
$836.86
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
24-FEB-67
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8504314065

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$836.861U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$836.861U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
TE1232554401
TRANSFORMER ENGINEERS CO A DIV OF STANDARD INDUSTRIES INC
H59ETX1B
5038564053
COILTRON INC DIV COILTRON
A515TX
ST2885097102
STERLING TRANSFORMER CORP
H596TXB
7024504386
MAGNETEK INC HUNTINGTON DIV
R595TX
722804-3105869
RAYTHEON COMPANY DIV RMD STRATEGIC
A32ATX3D
712005614
ALTEC LANSING CORP SOUND PRODUCTS DIV
H595TX3B
702450LG51
MAGNETEK INC LIGHTING PRODUCTS GROUP
A525ZZ

Characteristics

NOMINAL THREAD SIZESINGLE GROUP INCHES 0.250
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC NOMINAL 5.0
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 7
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED HOLE(S)
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC NOMINAL 300.0
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC NOMINAL 5.0
WINDING POWER RATINGSINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 13.0
WINDING POWER RATINGSINGLE COMPONENT FOURTH SECONDARY VOLTS-AMPERES 156.8
WINDING POWER RATINGSINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 2.0
WINDING POWER RATINGSINGLE COMPONENT THIRD SECONDARY VOLTS-AMPERES 13.0
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC KILOVOLTS NOMINAL 2.60
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC KILOVOLTS NOMINAL 1.425
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 6.50
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 110.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 120.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC KILOVOLTS NOMINAL 2.60
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC NOMINAL 110.0
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYSOLDER STUD 23
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.500
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
MAXIMUM TRANSFORMER POWER RATINGSINGLE COMPONENT VOLT-AMPERE 284.4
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL
BODY LENGTHINCHES MINIMUM 4.870 AND INCHES MAXIMUM 5.000
BODY WIDTHINCHES MINIMUM 4.120 AND INCHES MAXIMUM 4.250
BODY HEIGHTINCHES MINIMUM 4.620 AND INCHES MAXIMUM 4.750
MAXIMUM OPERATING TEMPCELSIUS 130.0
INCLOSURE TYPEHERMETICALLY SEALED
SPECIAL FEATURESONE PRIMARY WINDING; SEVEN SECONDARY WINDINGS WITH THE 2ND AND 7TH WINDING CENTER TAPPED AND THE 6TH WINDING MULTIPLE TAPPED W/O CENTER TAP
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 4.250

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-FEB-01YA81YA
ZF01ZF01-APR-91ZF81ZF
ZR01ZR01-JUL-97ZR81ZR
N9BNDN1G01-JUN-06ZGHGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
ZZZZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
ZZZ
Special requirement: see the specific drawing or instruction provided
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
Z
Special requirements - See specific instructions or drawings provided.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
Z
Special requirements – See specific instructions or drawings provided
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Z
Special requirement.
Lvl c
Z
Special requirement – see specific instructions or drawings provided.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
SPECIAL PACKAGING INSTRUC

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI no
D149335002
SPI date
88022

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
22-MAY-1968
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.