Catalog item
Request a quoteTRANSFORMER,POWER
5950FSC
00NCB code
945-0650Item number
NIIN 00-945-0650
- Unit price
- $956.79
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 32496
- PINC
- 0032496
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 18-FEB-66
- Precious metals indicator
- A
- Hazardous material indicator
- P
- FedMall
- Y
Management
- Effective date
- 01-OCT-2026
- Major organizational entity
- DS
- Acquisition advice code
- X
- Source of supply
- SMS
- Unit of issue
- EA
- Unit of measure quantity
- 0.0000
- Unit price
- $956.79
- Quantity per unit pack
- 1
- Controlled inventory item code
- U
- Shelf-life code
- 0
- Management control
- -------
- Net price
- $0.00
- USC
- I
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| 73C828-001 | 72964 ROBERT M. HADLEY COMPANY, INC. | A | 5 | 2 | 6 | TX | ||
| 172059-000 | 81413 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC. DBA BAE SYSTEMS | A | 5 | 2 | 5 | TX | 3 | D |
| 73C828-001 | 90095 INRCORE, LLC DIV INRCORE | A | 5 | 2 | 6 | TX | ||
| 73C828-001 | 04660 AIL SYSTEMS INC SUB OF EATON CORP | H | 3 | 9 | A | TX | 3 | D |
| 8201425-001 | 04660 AIL SYSTEMS INC SUB OF EATON CORP | H | 5 | 9 | 5 | KE | 3 | B |
Characteristics
| BODY WIDTH | INCHES MINIMUM 2.734 AND INCHES MAXIMUM 2.766 |
|---|---|
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE |
| TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
| MAXIMUM OPERATING TEMP | CELSIUS 170.0 |
| TERMINAL TYPE AND QUANTITY | TURRET 13 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY AMPERES AC NOMINAL 4.0 |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY FIRST CENTER GROUP INCHES MINIMUM 2.234 AND INCHES MAXIMUM 2.266 |
| INCLOSURE TYPE | FULLY INCLOSED |
| MOUNTING FACILITY QUANTITY | 2 |
| MOUNTING FACILITY QUANTITY | 4 |
| MOUNTING METHOD | ALL GROUPINGS THREADED HOLE(S) |
| WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 2 |
| NOMINAL THREAD SIZE | FIRST GROUP INCHES 0.138 |
| NOMINAL THREAD SIZE | FOURTH GROUP INCHES 0.164 |
| WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| BODY LENGTH | INCHES MINIMUM 3.609 AND INCHES MAXIMUM 3.641 |
| FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY FOURTH CENTER GROUP INCHES MINIMUM 2.115 AND INCHES MAXIMUM 2.135 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SECOND CENTER GROUP INCHES MINIMUM 2.734 AND INCHES MAXIMUM 2.766 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY THIRD CENTER GROUP INCHES MINIMUM 2.734 AND INCHES MAXIMUM 2.766 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY FOURTH CENTER GROUP INCHES MINIMUM 1.052 AND INCHES MAXIMUM 1.072 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SECOND CENTER GROUP INCHES MINIMUM 2.234 AND INCHES MAXIMUM 2.266 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY THIRD CENTER GROUP INCHES MINIMUM 2.234 AND INCHES MAXIMUM 2.266 |
| OVERALL HEIGHT | INCHES MINIMUM 1.922 AND INCHES MAXIMUM 1.954 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 198.90 |
| TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 04660-73C828 |
| THREAD SERIES DESIGNATOR | ALL GROUPINGS UNIFIED NATIONAL COARSE (UNC) |
| WINDING POWER RATING | SINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 29.13 |
| WINDING POWER RATING | SINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 26.0 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 39.20 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 6.50 |
| NOMINAL THREAD SIZE | THIRD GROUP INCHES 0.112 |
| NOMINAL THREAD SIZE | SECOND GROUP INCHES 0.112 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC NOMINAL 743.0 |
MOE rules
- MOE rule
- DGX1
- MOE CD
- DS
- AMC
- 1
- AMSC
- C
- Date assigned
- 01-JUN-06
- PICA
- GX
- PICA LOA
- 01
- Auth collab
- GX
- Supp collab
- TX
- Fmr MOE rl
- DTX1
Freight
- ACTY CD
- PA
- NMFC
- 063420
- NMFC sub
- Z
- Uniform freight class
- 35355
- Less than truckload
- W
- Water commodity code
- 595
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- TRANSFORMERS,NOI,OR TRANSFORMER PAR
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 10Physical protection
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- DOAny suitable fiber box included in this table may be used (see J.4.9.1).
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- UItems or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
- Unit pack weight
- 1.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.1000
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
- Supplemental instructions
- IP025: PACKAGING, MARKING,
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 74275
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 06-JAN-1978
- NIIN status code
- 0
Request a quote