Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
950-9846Item number
NIIN 00-950-9846
Request a quote
Unit price
$331.11
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-62
Precious metals indicator
U
Hazardous material indicator
P

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
X
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$331.11
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
TF4SX01GA20981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A513TX3D
MIL-T-2781349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX4B
MIL-PRF-2781349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
MS16471-196906
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX3D

Characteristics

MOUNTING METHODSINGLE GROUP THREADED STUD(S)
MAXIMUM OPERATING TEMPCELSIUS 130.0
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.125
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.750
WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE SECONDARY AMPERES AC MAXIMUM 20.0
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 105.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 125.00
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE
FREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 380.0 AND KILOHERTZ MAXIMUM 1.0
MOUNTING FACILITY QUANTITY4
BODY HEIGHTINCHES NOMINAL 3.812
INCLOSURE TYPEHERMETICALLY SEALED
BODY WIDTHINCHES NOMINAL 2.375
TERMINAL TYPE AND QUANTITYTURRET 7
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 1
THREAD QUANTITY PER INCH32
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.138
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-T-27
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
BODY LENGTHINCHES NOMINAL 2.750
SPECIFICATION/STANDARD DATAGOVERNMENT STANDARD 96906--S16471

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedPICAPICA LOAAuth collab
ZC01ZC01-APR-91ZC81ZC
DGX1DS1G01-JAN-26GX01GX

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
3.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0270
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
15-DEC-1974
NIIN status code
0

Request a quote