Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
972-9873Item number
NIIN 00-972-9873
Request a quote
Unit price
$3,511.04
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
07-OCT-66
Precious metals indicator
A
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$3,511.041U0ZQ2200X-$0.00A
01-OCT-2026DMJSMSEA0.0000$3,511.041U0Z15B2B--$0.00M
01-OCT-2026DSJSMSEA0.0000$3,511.041U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
126-27173B150
RAYTHEON COMPANY DBA RAYTHEON CO
A524TX
126-271749956
RAYTHEON COMPANY DIV CORP
A594TX4B
126-271754X10
RAYTHEON COMPANY
A525ZZ
874A172149
ELECTRONIC TRANSFORMER CORP DIV ELECTRONIC TRANSFORMER CORPORATION
A525TX
1017521196256
THORDARSON INC
A525TX4D
1017521118876
US ARMY AVIATION AND MISSILE COMMAND
A32ATX3D

Characteristics

WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE AND MOUNTING
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
MOUNTING FACILITY QUANTITY4
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.164
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC NOMINAL 520.0
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC NOMINAL 50.0
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC NOMINAL 520.0
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC NOMINAL 85.0
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS MAXIMUM 42.30
OVERALL LENGTHINCHES MINIMUM 3.063 AND INCHES MAXIMUM 3.187
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 8
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS MAXIMUM 42.30
MOUNTING METHODSINGLE GROUP THREADED STUD(S)
SPECIAL FEATURES1 PRIMARY WINDING; 8 SECONDARY WNDNGS
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYSOLDER STUD 18
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS MAXIMUM 12.85
MAXIMUM OPERATING TEMPCELSIUS 130.0
INCLOSURE TYPEHERMETICALLY SEALED
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS MAXIMUM 19.30
RELIABILITY INDICATORNOT ESTABLISHED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
OVERALL HEIGHTINCHES MINIMUM 3.022 AND INCHES MAXIMUM 3.178
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 240.00
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 2.484 AND INCHES MAXIMUM 2.516
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.484 AND INCHES MAXIMUM 1.516
OVERALL WIDTHINCHES MINIMUM 3.000 AND INCHES MAXIMUM 3.124

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WG01WG01-OCT-17WG81WG
YB01YB01-SEP-08YB81YB
YD01YD01-SEP-16YD81YD
ZH01ZH01-APR-91ZH81ZH
ZJ01ZJ01-APR-25ZJ81ZJ
ZS01ZS01-APR-91ZS81ZS
ZU01ZU01-AUG-95ZU81ZU
A918DA5C01-NOV-05ZCDGX01CD5DCD GXBDA196
MC49DM5C01-NOV-05ZPAGX01PA5DGX PAMC13
VJ01VJ01-DEC-18VJ81VJ

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Marine Corps

SAC
1
CEC
5
MEC
B2
MIC
B

Freight

ACTY CD
BD
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
3.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.1520
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
22-MAY-1968
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.