Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
984-3950Item number
NIIN 00-984-3950
Request a quote
Unit price
$489.36
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-62
Precious metals indicator
U
Hazardous material indicator
P

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$489.361U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$489.361U0NSF9EH-V$0.00F
01-OCT-2026DNJSMSEA0.0000$489.361U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$489.361U0N-------$0.00I
01-OCT-2026GPJSMSEA0.0000$489.361U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
206230428527
L3HARRIS TECHNOLOGIES, INC.
A595TX1B
2062304G00128527
L3HARRIS TECHNOLOGIES, INC.
A591TX4B
ES98480223
UNITED TRANSFORMER CORP SUB OF OPT INDUSTRIES INC
A595TX4B
BTC1264089870
BERKSHIRE TRANSFORMER
A595TXB
206230490348
ITT FEDERAL LABORATORIES DIV OF INTERNATIONAL TELEPHONE AND TELEGRAPH CORP
HC15ZZAC
R10230998330
OECO, LLC
A525TX
10230998330
OECO, LLC
A595TX3B
25N21503598738
HERLEY CHICAGO DBA STEWART WARNER ELECTRONICS
A32ATX3D
ES98403776
ESCO INC
H595TX3B
ES98415634
MAGNETIKA INC
A525TX

Characteristics

WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 165.00
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 1.0
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.940
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 60.0
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.600
RELIABILITY INDICATORNOT ESTABLISHED
OVERALL LENGTHINCHES MAXIMUM 3.297
MOUNTING METHODSINGLE GROUP UNTHREADED HOLE(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 5
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 335.0
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC MAXIMUM 20.0
INCLOSURE TYPEFULLY INCLOSED
SPECIAL FEATURES1PRIMARY WINDING; 5SECONDARY WINDINGS
TERMINAL TYPE AND QUANTITYTURRET 13
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 40.00
OVERALL HEIGHTINCHES MAXIMUM 1.516
OVERALL WIDTHINCHES MAXIMUM 2.156
MOUNTING HOLE DIAMETERSINGLE GROUP INCHES NOMINAL 0.173
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 160.00
MOUNTING FACILITY QUANTITY4
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 26.00

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YB01YB01-APR-91YB81YB
ZG01ZG01-APR-91ZG81ZG
ZI01ZI01-NOV-20ZI81ZI
ZH01ZH01-APR-91ZH81ZH
ZR01ZR01-APR-91ZR81ZR
ZU01ZU01-APR-08ZU81ZU
ZW01ZW01-DEC-05ZW81ZW
A918DA1R01-JUN-06ZCDGX01CD5DCD GXCLA196
C911GP1R01-JUN-06GX01XG5DXG GXC007
FXGXDF1R01-JUN-06ZSXGX01SX5DGX TUFXTX
N9BNDN1R01-JUN-06ZGHGX01GH5DGXGT KENIND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
1.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0170
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
17-JUL-1967
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59505950-00-074-4619701-JUL-2026A
59505950-00-018-8807702-JUL-2026A

Request a quote