Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
990-9057Item number
NIIN 00-990-9057
Request a quote
Unit price
$3,632.48
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
23-MAR-67
Precious metals indicator
U
Hazardous material indicator
P

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
Y
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$3,632.48
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Recoverability code
N
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
6298756208
TOPAZ INC SUB OF SQUARE D CO POWERMARK DIV
H595TXB
5058664053
COILTRON INC DIV COILTRON
A525ZZ
50586T6976
PEGASUS SAVUNMA SANAYI VE TICARET ANONIM SIRKETI
A525ZW4A
A812506049
SQUARE D CO EPE/TOPAZ
H596TX1B
A812513786
MAGNETIC DEVICES INC
H596TXB
1017837118876
US ARMY AVIATION AND MISSILE COMMAND
A32ATX3D

Characteristics

BODY LENGTHINCHES MAXIMUM 2.750
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES DC MAXIMUM 100.0
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.560
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP THREADED STUD(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 3
BODY WIDTHINCHES MAXIMUM 2.000
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTURRET 15
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 20.37 AND AC VOLTS NOMINAL 26.80 AND AC VOLTS NOMINAL 33.23 AND AC VOLTS NOMINAL 53.60 AND AC VOLTS NOMINAL 199.80
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 25.20
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.312
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY MILLIAMPERES DC MAXIMUM 100.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL AND INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 240.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 3.75 AND AC VOLTS NOMINAL 9.10
BODY HEIGHTINCHES MAXIMUM 1.560
MAXIMUM OPERATING TEMPCELSIUS 60.0
INCLOSURE TYPEFULLY INCLOSED
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.138
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES DC MAXIMUM 30.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedPICAPICA LOAAuth collab
VJ01VJ01-DEC-18VJ81VJ
WG01WG01-OCT-17WG81WG
YB01YB01-APR-98YB81YB
YD01YD01-SEP-16YD81YD
YJ01YJ01-APR-91YJ81YJ
ZH01ZH01-APR-91ZH81ZH
ZJ01ZJ01-APR-25ZJ81ZJ
ZN01ZN01-APR-91ZN81ZN
ZS01ZS01-APR-91ZS81ZS
ZU01ZU01-AUG-95ZU81ZU
ZW01ZW01-NOV-14ZW81ZW
DGX1DS1G01-AUG-11GX01GX

Freight

ACTY CD
BD
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
1.3000
UP SZ MAXB
2.00000
UP SZ MAXL
2.80000
UP SZ MAXH
1.60000
Unit pack cube
0.0350
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
22-MAY-1968
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.