Catalog item

TRANSFORMER,POWER

5950FSC
01NCB code
042-6835Item number
NIIN 01-042-6835
Request a quote
Unit price
$370.52
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
14-JUN-77
Precious metals indicator
U
ADP equipment code
0
Hazardous material indicator
P
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$370.521U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$370.521U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
T9147B07119
KAPITAL MAGNETIC CORP
H595KE1B
161005615476
COMPAQ FEDERAL LLC
A32BTX1A

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
OVERALL LENGTHINCHES MAXIMUM 5.750
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 4.940
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 4.130
OVERALL HEIGHTINCHES MAXIMUM 4.500
OVERALL WIDTHINCHES MAXIMUM 5.750
MOUNTING SLOT WIDTHSINGLE GROUP INCHES NOMINAL 0.250
FREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 48.0 AND HERTZ MAXIMUM 63.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
INCLOSURE TYPEFULLY INCLOSED
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSINGLE GROUP SLOT
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 2 AND SECONDARY 4
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY AMPERES AC NOMINAL 4.4
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES AC NOMINAL 6.6
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC NOMINAL 11.0
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES AC NOMINAL 2.2
WINDING POWER RATINGSINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 23.1
WINDING POWER RATINGSINGLE COMPONENT THIRD SECONDARY VOLTS-AMPERES 75.9
WINDING POWER RATINGSINGLE COMPONENT FOURTH SECONDARY VOLTS-AMPERES 127.6
WINDING POWER RATINGSINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 319.0
WINDING OPERATING VOLTAGESINGLE COMPONENT ALL PRIMARY AC VOLTS NOMINAL 115.00
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS MINIMUM 25.00 AND AC VOLTS MAXIMUM 29.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS MINIMUM 9.90 AND AC VOLTS MAXIMUM 11.50
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS MINIMUM 25.00 AND AC VOLTS MAXIMUM 29.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 10.50
PROPRIETARY CHARACTERISTICSPACS
TERMINAL TYPE AND QUANTITYWIRE LEAD 18

MOE rules

MOE rule
N9BN
MOE CD
DN
AMC
3
AMSC
H
Date assigned
01-JUN-06
IMC
Z
IMCA
GH
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX
Supp collab
KE
Fmr MOE rl
N9ND

Service data

Navy

COG
9B

Freight

ACTY CD
KE
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69FZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
19.3000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.1880
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TU
Dt stdzn dec
04-MAR-1980
NIIN status code
0

Request a quote