Catalog item
Request a quoteTRANSFORMER,POWER
5950FSC
01NCB code
050-1220Item number
NIIN 01-050-1220
- Unit price
- $2,108.72
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 32496
- PINC
- 0032496
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-NOV-77
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- P
- FedMall
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $2,108.72 | 1 | U | 0 | 9B----- | $0.00 | N |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $2,108.72 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
Characteristics
| RELIABILITY INDICATOR | NOT ESTABLISHED |
|---|---|
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 3.740 AND INCHES MAXIMUM 3.760 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.990 AND INCHES MAXIMUM 2.010 |
| FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| BODY LENGTH | INCHES MAXIMUM 4.250 |
| BODY WIDTH | INCHES MAXIMUM 2.500 |
| BODY HEIGHT | INCHES MAXIMUM 1.875 |
| MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| INCLOSURE TYPE | FULLY INCLOSED |
| MOUNTING FACILITY QUANTITY | 4 |
| MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.138 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY AMPERES AC NOMINAL 10.0 |
| WINDING POWER RATING | SINGLE COMPONENT SINGLE SECONDARY VOLTS-AMPERES 62.0 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 118.50 AND AC VOLTS NOMINAL 122.00 AND AC VOLTS NOMINAL 125.50 AND AC VOLTS NOMINAL 129.00 AND AC VOLTS NOMINAL 132.50 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 6.20 |
| THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TERMINAL TYPE AND QUANTITY | TURRET 10 |
MOE rules
- MOE rule
- N9BN
- MOE CD
- DN
- AMC
- 3
- AMSC
- C
- Date assigned
- 01-JUN-06
- IMC
- Z
- IMCA
- HD
- PICA
- GX
- PICA LOA
- 01
- SICA
- GH
- SICA LOA
- 5D
- Auth collab
- GX
- Supp collab
- HD GT JB
- Fmr MOE rl
- N9ND
Service data
Navy
- COG
- 9B
Freight
- ACTY CD
- HD
- NMFC
- 063420
- NMFC sub
- Z
- Uniform freight class
- 35355
- Less than truckload
- W
- Water commodity code
- 595
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- TRANSFORMERS,NOI,OR TRANSFORMER PAR
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69Z0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- UItems or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
- Unit pack weight
- 2.3000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0470
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- IP025: PACKAGING, MARKING,
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 04-NOV-1977
- NIIN status code
- 0
Request a quote